Dry-Swabbing/Image Analysis Technique for the Pharmaceutical Equipment Cleaning Validation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F12%3A43894833" target="_blank" >RIV/60461373:22310/12:43894833 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S1877705812028366" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1877705812028366</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.proeng.2012.07.436" target="_blank" >10.1016/j.proeng.2012.07.436</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dry-Swabbing/Image Analysis Technique for the Pharmaceutical Equipment Cleaning Validation
Popis výsledku v původním jazyce
This paper presents the development of a new technique using the dry-swabbing method for monitoring the contamination of pharmaceutical equipment. Black polyester wipes were used to improve the detection limit of the visual inspection. A standardized method of producing model impurity was used to produce known contamination of the model surface by a variety of compounds ranging from 0 to 500 mýg.dm-2. The sample contaminations were dry swabbed and evaluated by measuring the intensity of contamination using the computer image analysis. The detected intensities of contamination were always proportional to the amount of the impurity applied. The dry-swabbing method has been proven to be at least by one order of magnitude more sensitive than mere visual check.
Název v anglickém jazyce
Dry-Swabbing/Image Analysis Technique for the Pharmaceutical Equipment Cleaning Validation
Popis výsledku anglicky
This paper presents the development of a new technique using the dry-swabbing method for monitoring the contamination of pharmaceutical equipment. Black polyester wipes were used to improve the detection limit of the visual inspection. A standardized method of producing model impurity was used to produce known contamination of the model surface by a variety of compounds ranging from 0 to 500 mýg.dm-2. The sample contaminations were dry swabbed and evaluated by measuring the intensity of contamination using the computer image analysis. The detected intensities of contamination were always proportional to the amount of the impurity applied. The dry-swabbing method has been proven to be at least by one order of magnitude more sensitive than mere visual check.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Procedia Engineering
ISSN
1877-7058
e-ISSN
—
Svazek periodika
42
Číslo periodika v rámci svazku
September
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
447-453
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—