LSPR based sputtered thin Au film sensor system study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F15%3A43900374" target="_blank" >RIV/60461373:22310/15:43900374 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LSPR based sputtered thin Au film sensor system study
Popis výsledku v původním jazyce
Thin Au films of effective thickness 2-20 nm were prepared by sputtering method. The method of thermal dewetting was employed to alter the nanostructure of the films and the films were therefore annealed at 300oC for 1 h. Evolution of Au nano-islands during the annealing was studied by AFM method. UV-Vis spectroscopy documented changes of optical properties of the nanostructures, the evolution of localized surface plasmon resonance (LSPR) absorption band in particular. To study the sensitivity of the LSPR band absorption to the surrounding medium dielectric constant, experimental detection device was assembled. The device enabled observation of changes in the band absorption in real time and sensorgrams were obtained for the annealed Au films 2-20 nm thick. The highest sensitivity to saturated acetone vapors in air was found by the film 4 nm of effective thickness and the signal to noise ratio in this case reached SNR = 583.
Název v anglickém jazyce
LSPR based sputtered thin Au film sensor system study
Popis výsledku anglicky
Thin Au films of effective thickness 2-20 nm were prepared by sputtering method. The method of thermal dewetting was employed to alter the nanostructure of the films and the films were therefore annealed at 300oC for 1 h. Evolution of Au nano-islands during the annealing was studied by AFM method. UV-Vis spectroscopy documented changes of optical properties of the nanostructures, the evolution of localized surface plasmon resonance (LSPR) absorption band in particular. To study the sensitivity of the LSPR band absorption to the surrounding medium dielectric constant, experimental detection device was assembled. The device enabled observation of changes in the band absorption in real time and sensorgrams were obtained for the annealed Au films 2-20 nm thick. The highest sensitivity to saturated acetone vapors in air was found by the film 4 nm of effective thickness and the signal to noise ratio in this case reached SNR = 583.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Cansmart/SMN 2015
ISBN
978-0-9813815-2-7
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
141-148
Název nakladatele
Royal Military College of Canada
Místo vydání
Kingston
Místo konání akce
Vancouver
Datum konání akce
15. 7. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—