Air Purification and Filter Design for Mobile APU Based on PEM Fuel Cell
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F18%3A43915950" target="_blank" >RIV/60461373:22310/18:43915950 - isvavai.cz</a>
Výsledek na webu
<a href="http://ecst.ecsdl.org/content/87/1/189.abstract" target="_blank" >http://ecst.ecsdl.org/content/87/1/189.abstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1149/08701.0189ecst" target="_blank" >10.1149/08701.0189ecst</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Air Purification and Filter Design for Mobile APU Based on PEM Fuel Cell
Popis výsledku v původním jazyce
For optimal long time operation of PEM fuel cell it is necessary to ensure high purity of reacting gasses. For hydrogen it is related to the technology of its production and purification. Significantly more complicated situation is for oxidant if ambient air is used. Proper air filtration is necessary to prevent contact of mechanical and chemical pollutants with cathode catalyst. On the other hand the energy consumption of air blowers to compensate filters pressure drop decreases system efficiency. The air filter suitable for mobile APU unit was designed and constructed with respect to the absorption capacity of model pollutant at the same time reflecting its pressure drop.
Název v anglickém jazyce
Air Purification and Filter Design for Mobile APU Based on PEM Fuel Cell
Popis výsledku anglicky
For optimal long time operation of PEM fuel cell it is necessary to ensure high purity of reacting gasses. For hydrogen it is related to the technology of its production and purification. Significantly more complicated situation is for oxidant if ambient air is used. Proper air filtration is necessary to prevent contact of mechanical and chemical pollutants with cathode catalyst. On the other hand the energy consumption of air blowers to compensate filters pressure drop decreases system efficiency. The air filter suitable for mobile APU unit was designed and constructed with respect to the absorption capacity of model pollutant at the same time reflecting its pressure drop.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
<a href="/cs/project/VI20152019018" target="_blank" >VI20152019018: Vývoj a realizace nezávislého DC zdroje napájení s vodíkovým palivovým článkem</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ECS Transactions
ISBN
—
ISSN
1938-5862
e-ISSN
1938-5862
Počet stran výsledku
8
Strana od-do
189-196