Development of Smart Sensing Film with Nonbiofouling Properties for Potentiometric Detection of Local pH Changes Caused by Bacterial and Yeast Infections Around Orthopedic Implants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F22%3A43925151" target="_blank" >RIV/60461373:22310/22:43925151 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389013:_____/23:00568558 RIV/68407700:21220/23:00361293 RIV/00216208:11110/23:10451750 RIV/00064203:_____/23:10451750
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1002/admi.202201878" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/admi.202201878</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/admi.202201878" target="_blank" >10.1002/admi.202201878</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of Smart Sensing Film with Nonbiofouling Properties for Potentiometric Detection of Local pH Changes Caused by Bacterial and Yeast Infections Around Orthopedic Implants
Popis výsledku v původním jazyce
The local peri-implant pH changes caused by sterile inflammation and bacterial and fungal infections are studied herein. Then, a sensing electrode based on polyaniline and poly(2-methyl-2-oxazoline) on a titanium alloy support is developed for potentiometric detection of peri-implant pH changes to enable early detection of the aforementioned pathologies. The infected endoprosthesis area is shown to have an average pH of 0.79 units lower than the aseptic sample. The pH measurements of the individual pathogenic bacteria or pathogenic yeast reveal that Escherichia coli decreased the pH by 1.24 units, Staphylococcus aureus decreased the pH by 1.33 units and the methicillin-resistant Staphylococcus aureus bacteria decreased the pH from 7.2 to 5.6 during 10 h, followed by a subsequent increase to 6.4. The results are statistically significant (α = 0.01). Pseudomonas aeruginosa is not shown to change pH levels. On the other hand, the pathogenic yeast has the lowest recorded pH, which decreases from 5.8 to 4.8. This difference in pH can be used to identify the nature of the infection. The developed electrodes have a pH response between pH 5 and 8, with a Nernstian slope of −59.6/pH. The developed electrode can contribute to the next generation of biosensors
Název v anglickém jazyce
Development of Smart Sensing Film with Nonbiofouling Properties for Potentiometric Detection of Local pH Changes Caused by Bacterial and Yeast Infections Around Orthopedic Implants
Popis výsledku anglicky
The local peri-implant pH changes caused by sterile inflammation and bacterial and fungal infections are studied herein. Then, a sensing electrode based on polyaniline and poly(2-methyl-2-oxazoline) on a titanium alloy support is developed for potentiometric detection of peri-implant pH changes to enable early detection of the aforementioned pathologies. The infected endoprosthesis area is shown to have an average pH of 0.79 units lower than the aseptic sample. The pH measurements of the individual pathogenic bacteria or pathogenic yeast reveal that Escherichia coli decreased the pH by 1.24 units, Staphylococcus aureus decreased the pH by 1.33 units and the methicillin-resistant Staphylococcus aureus bacteria decreased the pH from 7.2 to 5.6 during 10 h, followed by a subsequent increase to 6.4. The results are statistically significant (α = 0.01). Pseudomonas aeruginosa is not shown to change pH levels. On the other hand, the pathogenic yeast has the lowest recorded pH, which decreases from 5.8 to 4.8. This difference in pH can be used to identify the nature of the infection. The developed electrodes have a pH response between pH 5 and 8, with a Nernstian slope of −59.6/pH. The developed electrode can contribute to the next generation of biosensors
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced Materials Interfaces
ISSN
2196-7350
e-ISSN
—
Svazek periodika
2201878
Číslo periodika v rámci svazku
2201878
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
000895528500001
EID výsledku v databázi Scopus
—