Influence of Intermetallic Particles on Localized Corrosion of Tin Alloy Organ Pipes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F25%3A43933494" target="_blank" >RIV/60461373:22310/25:43933494 - isvavai.cz</a>
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/epdf/10.1002/maco.12010?src=getftr&utm_source=clarivate&getft_integrator=clarivate" target="_blank" >https://onlinelibrary.wiley.com/doi/epdf/10.1002/maco.12010?src=getftr&utm_source=clarivate&getft_integrator=clarivate</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/maco.12010" target="_blank" >10.1002/maco.12010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Intermetallic Particles on Localized Corrosion of Tin Alloy Organ Pipes
Popis výsledku v původním jazyce
This work dealt with the evaluation of the effect of intermetallic particles in tin alloy on the localized corrosion of organ pipes. Typical intermetallic phases that occur in tin alloy of organ pipes (Cu6Sn5, FeSn2) were prepared. Together with tin, these intermetallic alloys were studied in an environment of artificial rainwater and an aggressive wet film from a church environment (containing acetate) to determine electrochemical parameters (free corrosion potential, polarization resistance, and Tafel slopes). These data were then used as input for the numerical simulation of the function of galvanic microcells in the alloy structure. The results show a local increase in corrosion attack up to hundreds of percent.
Název v anglickém jazyce
Influence of Intermetallic Particles on Localized Corrosion of Tin Alloy Organ Pipes
Popis výsledku anglicky
This work dealt with the evaluation of the effect of intermetallic particles in tin alloy on the localized corrosion of organ pipes. Typical intermetallic phases that occur in tin alloy of organ pipes (Cu6Sn5, FeSn2) were prepared. Together with tin, these intermetallic alloys were studied in an environment of artificial rainwater and an aggressive wet film from a church environment (containing acetate) to determine electrochemical parameters (free corrosion potential, polarization resistance, and Tafel slopes). These data were then used as input for the numerical simulation of the function of galvanic microcells in the alloy structure. The results show a local increase in corrosion attack up to hundreds of percent.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20500 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA22-05801S" target="_blank" >GA22-05801S: Příčiny a mechanismus degradace slitin cínu s nízkým obsahem legujících prvků</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION
ISSN
0947-5117
e-ISSN
1521-4176
Svazek periodika
76
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
1676-1683
Kód UT WoS článku
001499900300001
EID výsledku v databázi Scopus
2-s2.0-105006903817