Application of ion exchange resins to recovery of metals from decontamination solutions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22320%2F17%3A43913553" target="_blank" >RIV/60461373:22320/17:43913553 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of ion exchange resins to recovery of metals from decontamination solutions
Popis výsledku v původním jazyce
Three ion exchange resins were used for the selective removal of nickel (II), copper (II), cobalt (II), zinc (II), manganese (II) and iron (III+II) from synthetic solutions simulating AP-CITROX decontamination solution. In this study, we tested two chelating resins; Dowex M4195, Lewatit MonoPlus TP207 and strongly acidic cation exchange resin Lewatit MonoPlus SP112, all promising in acidic solutions. The efficiencies of resins were tested in column experiments. The aqueous samples were analyzed by atomic absorption spectroscopy. The chelating resin, Dowex M4195 showed the best results for nickel, cobalt, copper and iron selective sorption from model solution. On the other hand the metal removal by Lewatit MonoPlus TP207 was not efficient. The zinc and manganese sorption results onto Lewatit MonoPlus SP112 were very promising. Thus, to achieve high selectivity of extracting tested metals we tried the series column circuits with DowexM4195 and Lewatit MonoPlus SP112. Based on this study, it would appear that treatment of mixed metal wastes, generated by APCITROX decontamination process, by ion exchange resins is a technically feasible process for removal and separation of metals, even in lower pH, such as pH=1.
Název v anglickém jazyce
Application of ion exchange resins to recovery of metals from decontamination solutions
Popis výsledku anglicky
Three ion exchange resins were used for the selective removal of nickel (II), copper (II), cobalt (II), zinc (II), manganese (II) and iron (III+II) from synthetic solutions simulating AP-CITROX decontamination solution. In this study, we tested two chelating resins; Dowex M4195, Lewatit MonoPlus TP207 and strongly acidic cation exchange resin Lewatit MonoPlus SP112, all promising in acidic solutions. The efficiencies of resins were tested in column experiments. The aqueous samples were analyzed by atomic absorption spectroscopy. The chelating resin, Dowex M4195 showed the best results for nickel, cobalt, copper and iron selective sorption from model solution. On the other hand the metal removal by Lewatit MonoPlus TP207 was not efficient. The zinc and manganese sorption results onto Lewatit MonoPlus SP112 were very promising. Thus, to achieve high selectivity of extracting tested metals we tried the series column circuits with DowexM4195 and Lewatit MonoPlus SP112. Based on this study, it would appear that treatment of mixed metal wastes, generated by APCITROX decontamination process, by ion exchange resins is a technically feasible process for removal and separation of metals, even in lower pH, such as pH=1.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10503 - Water resources
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 5th International Conference on Chemical Technology
ISBN
978-80-86238-65-4
ISSN
—
e-ISSN
neuvedeno
Počet stran výsledku
5
Strana od-do
526-530
Název nakladatele
Česká společnost průmyslové chemie (ČSPCH)
Místo vydání
Praha
Místo konání akce
Mikulov
Datum konání akce
10. 4. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—