Apparatus for testing He leakage through flange gaskets at elevated pressure and temperature
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22320%2F21%3A43921940" target="_blank" >RIV/60461373:22320/21:43921940 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0149197021001955?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0149197021001955?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.pnucene.2021.103831" target="_blank" >10.1016/j.pnucene.2021.103831</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Apparatus for testing He leakage through flange gaskets at elevated pressure and temperature
Popis výsledku v původním jazyce
The study focuses on the measurement of He leakage from the cooling circuits of the helium-cooled GFR (gascooled fast reactor). It is necessary to measure two phenomena, namely losses of He from the pipeline circuit through flange joints and the contamination of helium inside the pipeline by the diffusion of permanent gases from the external environment (i.e. against the pressure gradient). Methods for determining the tightness of flange joints according to current standards are not fully suitable for these purposes. For this reason, a selfdesigned apparatus was constructed in order to measure both effects at pressures up to 20 MPa and temperatures within the range from ambient values up to 400 ◦C. Gas chromatography with a PDHID detector was used to determine the rate of diffusion of nitrogen and other permanent gases through the flange into pure He. On the other hand, the He leakage through the piping flange joint into the external environment was measured using a gas chromatograph with a high sensitivity TCD. The issues of heat distribution within the high-pressure measuring vessel are discussed as well.
Název v anglickém jazyce
Apparatus for testing He leakage through flange gaskets at elevated pressure and temperature
Popis výsledku anglicky
The study focuses on the measurement of He leakage from the cooling circuits of the helium-cooled GFR (gascooled fast reactor). It is necessary to measure two phenomena, namely losses of He from the pipeline circuit through flange joints and the contamination of helium inside the pipeline by the diffusion of permanent gases from the external environment (i.e. against the pressure gradient). Methods for determining the tightness of flange joints according to current standards are not fully suitable for these purposes. For this reason, a selfdesigned apparatus was constructed in order to measure both effects at pressures up to 20 MPa and temperatures within the range from ambient values up to 400 ◦C. Gas chromatography with a PDHID detector was used to determine the rate of diffusion of nitrogen and other permanent gases through the flange into pure He. On the other hand, the He leakage through the piping flange joint into the external environment was measured using a gas chromatograph with a high sensitivity TCD. The issues of heat distribution within the high-pressure measuring vessel are discussed as well.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Progress in Nuclear Energy
ISSN
0149-1970
e-ISSN
—
Svazek periodika
139
Číslo periodika v rámci svazku
September 2021
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
103831
Kód UT WoS článku
000689718500005
EID výsledku v databázi Scopus
2-s2.0-85108274971