Application of Supercritical Fluid Extraction in Multi-residue Pesticide Analysis of Plant Matrices
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F03%3A00008890" target="_blank" >RIV/60461373:22330/03:00008890 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of Supercritical Fluid Extraction in Multi-residue Pesticide Analysis of Plant Matrices
Popis výsledku v původním jazyce
Sample preparation based on selective supercritical fluid extraction (SFE) prior to gas chromatographic (GC) analysis of several groups of pesticides (organophosphates, organochlorines, pyrethroides and others) in cereals, cereal products, vegetables andfruits has been used. Electron capture detector (ECD) and nitrogen phosphorus detector (NPD) for parallel detection of investigated compounds were used. The obtained results showed satisfactory recoveries for most of compounds (more than 70%) and suff icient selectivity of extraction, namely for GC-NPD amenable compounds. The optimised procedure was successfully compared with conventional liquid extraction followed by GPC clean up in the frame of inter-laboratory study.
Název v anglickém jazyce
Application of Supercritical Fluid Extraction in Multi-residue Pesticide Analysis of Plant Matrices
Popis výsledku anglicky
Sample preparation based on selective supercritical fluid extraction (SFE) prior to gas chromatographic (GC) analysis of several groups of pesticides (organophosphates, organochlorines, pyrethroides and others) in cereals, cereal products, vegetables andfruits has been used. Electron capture detector (ECD) and nitrogen phosphorus detector (NPD) for parallel detection of investigated compounds were used. The obtained results showed satisfactory recoveries for most of compounds (more than 70%) and suff icient selectivity of extraction, namely for GC-NPD amenable compounds. The optimised procedure was successfully compared with conventional liquid extraction followed by GPC clean up in the frame of inter-laboratory study.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Food Research and Technology
ISSN
1438-2377
e-ISSN
—
Svazek periodika
216
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
68-74
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—