Kinetika degradace benzínových par v poraverovém biofiltru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F05%3A00015575" target="_blank" >RIV/60461373:22330/05:00015575 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Kinetics of Gasoline Vapor Removal in a Poraver Filled Biofilter
Popis výsledku v původním jazyce
The objective of this study was to evaluate the kinetic constants of gasoline degradation in waste gases using a bench-scale biofilter with ID 100 mm and a bed height of 750 mm. The overall, aliphatic and aromatic fractions were analyzed separately. Theconcentrations of pollutants were measured at various points down the bio-reactor to give a concentration profile. The packing material was Poraver (Dennert Poraver GmbH, Germany) with a grain size of 8 - 16 mm. The inlet concentration was kept constantat 250 mg m-3 and the biofilter was loaded by air flow rate.The results showed, as expected, that increasing the residence times improved the removal rates. The aromatic components were removed more rapidly and more completely than the aliphatic compounds. To determine the most appropriate form of the Ottengraf model. The zero order kinetic model was superior. (For aliphatic compounds, use the reaction limited equation and for the aromatic components, diffusion limited was marginally bet
Název v anglickém jazyce
Kinetics of Gasoline Vapor Removal in a Poraver Filled Biofilter
Popis výsledku anglicky
The objective of this study was to evaluate the kinetic constants of gasoline degradation in waste gases using a bench-scale biofilter with ID 100 mm and a bed height of 750 mm. The overall, aliphatic and aromatic fractions were analyzed separately. Theconcentrations of pollutants were measured at various points down the bio-reactor to give a concentration profile. The packing material was Poraver (Dennert Poraver GmbH, Germany) with a grain size of 8 - 16 mm. The inlet concentration was kept constantat 250 mg m-3 and the biofilter was loaded by air flow rate.The results showed, as expected, that increasing the residence times improved the removal rates. The aromatic components were removed more rapidly and more completely than the aliphatic compounds. To determine the most appropriate form of the Ottengraf model. The zero order kinetic model was superior. (For aliphatic compounds, use the reaction limited equation and for the aromatic components, diffusion limited was marginally bet
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA104%2F05%2F0194" target="_blank" >GA104/05/0194: Degradace směsí uhlovodíků a jiných těkavých organických polutantů v biofiltrech</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů