CZE separace enentiomerů lisuridu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F05%3A00016006" target="_blank" >RIV/60461373:22330/05:00016006 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CZE separation of enantiomers of lisuride
Popis výsledku v původním jazyce
Lisuride is an ergot alkaloid derivative with dopaminergic activity. It is used for treatment of Parkinsonism and some other diseases associated with high level of prolactine. Lisuride is a chiral compound derived from natural ergot alkaloids. A new capillary zone electrophoresis (CZE) method capable of separating the enantiomers of lisuride was developed. Using the optimized conditions (acidic electrolyte with the addition of gamma-cyclodextrin ( -CD)) as low as 0.02% of undesirable l-lisuride can be detected. Selected method characteristics, i.e., linearity (0#20 mg/l), precision (2.0% at 5 mg/l), and accuracy (101#4% at 5 mg/l) were evaluated. The optimized method was applied for the analysis of real batches of Lisuride hydrogenmaleate and Lisuridebase manufactured by IVAX Pharmaceuticals. It was found that they contain lessthan 0.02% of undesirable l-enantiomer.
Název v anglickém jazyce
CZE separation of enantiomers of lisuride
Popis výsledku anglicky
Lisuride is an ergot alkaloid derivative with dopaminergic activity. It is used for treatment of Parkinsonism and some other diseases associated with high level of prolactine. Lisuride is a chiral compound derived from natural ergot alkaloids. A new capillary zone electrophoresis (CZE) method capable of separating the enantiomers of lisuride was developed. Using the optimized conditions (acidic electrolyte with the addition of gamma-cyclodextrin ( -CD)) as low as 0.02% of undesirable l-lisuride can be detected. Selected method characteristics, i.e., linearity (0#20 mg/l), precision (2.0% at 5 mg/l), and accuracy (101#4% at 5 mg/l) were evaluated. The optimized method was applied for the analysis of real batches of Lisuride hydrogenmaleate and Lisuridebase manufactured by IVAX Pharmaceuticals. It was found that they contain lessthan 0.02% of undesirable l-enantiomer.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GM - Potravinářství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA525%2F03%2F0351" target="_blank" >GA525/03/0351: Použití kapilární elektroforesy pro analýzu bioaktivních látek v potravinách</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1066
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
255-258
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—