Degradace rozpouštědel podél výšky lože v biotrikling filtru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F05%3A00016388" target="_blank" >RIV/60461373:22330/05:00016388 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Paint Solvent Components Degradation from their Mixture along the Biotrickling Bed Height-sborník
Popis výsledku v původním jazyce
A biotrickling filter was used for the treatment of waste gas. Pollutants tested included aromatic hydrocarbons - toluene, xylenes, oxygenated compounds - methyl ethyl ketone, methyl isobutyl ketone and ester - n-butyl acetate.In the first phase of the experiments the biotrickling filter was loaded by increasing the inlet concentration of aromatic hydrocarbons in the pollutant mixture from 6 gC.m3.h 1 to 16 gC.m 3.h 1. It resulted in a decrease of the degradation efficiency of toluene and xylenes to 60%. Almost no effect on the removal efficiency of hydrophilic compounds was observed. Secondly, the effect of an increasing amount of hydrophilic compounds in the mixture of all solvents on the degradation efficiency was investigated. The loading by ketones and n butyl acetate caused not only a quite rapid drop of REAROM, but also a slight decrease of REKET.
Název v anglickém jazyce
Paint Solvent Components Degradation from their Mixture along the Biotrickling Bed Height-sborník
Popis výsledku anglicky
A biotrickling filter was used for the treatment of waste gas. Pollutants tested included aromatic hydrocarbons - toluene, xylenes, oxygenated compounds - methyl ethyl ketone, methyl isobutyl ketone and ester - n-butyl acetate.In the first phase of the experiments the biotrickling filter was loaded by increasing the inlet concentration of aromatic hydrocarbons in the pollutant mixture from 6 gC.m3.h 1 to 16 gC.m 3.h 1. It resulted in a decrease of the degradation efficiency of toluene and xylenes to 60%. Almost no effect on the removal efficiency of hydrophilic compounds was observed. Secondly, the effect of an increasing amount of hydrophilic compounds in the mixture of all solvents on the degradation efficiency was investigated. The loading by ketones and n butyl acetate caused not only a quite rapid drop of REAROM, but also a slight decrease of REKET.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
EI - Biotechnologie a bionika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA104%2F05%2F0194" target="_blank" >GA104/05/0194: Degradace směsí uhlovodíků a jiných těkavých organických polutantů v biofiltrech</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Intenational Congress Biotechniques for Air Pollution Control
ISBN
84-9749-163-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
371-376
Název nakladatele
Universidade da Coruna
Místo vydání
La Coruna
Místo konání akce
La Coruna
Datum konání akce
5. 10. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—