This study reports development of an immunostrip test for thiabendazole detection based on indirect competitive principle using carbon particles as a label. Nitrocellulose membrane strip was coated with a thiabendazole-protein conjugate in the defined test zone. In flow of an antibody-carbon complex and thiabendazole along the strip, the intensity of black colour formed in the test line reflected the thiabendazole concentration and semi-quantitative estimation could be carried out visually. The optimized test was accomplished within 10 min and the visual detection limit was achieved 0.25 ngmL-1 of standard sample. Moreover, immunostrip was evaluated quantitatively using scanning densitometry. Based on standard curve, the detection limit of the proposedtest was as low as 0.08?0.03 ngmL-1 with an IC50 value of 0.60?0.08 ngmL-1 and a linear working range of 0.11?4.13 ngmL-1. Results of testing precision, stability, and specificity demonstrated that the assay provided a reliable performan
Název v anglickém jazyce
Strip-based immunoassay for rapid detection of thiabendazole.
Popis výsledku anglicky
This study reports development of an immunostrip test for thiabendazole detection based on indirect competitive principle using carbon particles as a label. Nitrocellulose membrane strip was coated with a thiabendazole-protein conjugate in the defined test zone. In flow of an antibody-carbon complex and thiabendazole along the strip, the intensity of black colour formed in the test line reflected the thiabendazole concentration and semi-quantitative estimation could be carried out visually. The optimized test was accomplished within 10 min and the visual detection limit was achieved 0.25 ngmL-1 of standard sample. Moreover, immunostrip was evaluated quantitatively using scanning densitometry. Based on standard curve, the detection limit of the proposedtest was as low as 0.08?0.03 ngmL-1 with an IC50 value of 0.60?0.08 ngmL-1 and a linear working range of 0.11?4.13 ngmL-1. Results of testing precision, stability, and specificity demonstrated that the assay provided a reliable performan
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA525%2F07%2F0618" target="_blank" >GA525/07/0618: Imunoanalýza pesticidů v dětské-kojenecké výživě a v džusech - vývoj rychlých a jednoduchých detekčních metod</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biosensors and Bioelectronics
ISSN
0956-5663
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
000277930000020
EID výsledku v databázi Scopus
—