Lateral resolution in NALDI MSI: back to the future
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F15%3A43897788" target="_blank" >RIV/60461373:22330/15:43897788 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388971:_____/15:00444876 RIV/61989592:15310/15:33156419
Výsledek na webu
<a href="http://link.springer.com/article/10.1007%2Fs00216-014-8294-6" target="_blank" >http://link.springer.com/article/10.1007%2Fs00216-014-8294-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-014-8294-6" target="_blank" >10.1007/s00216-014-8294-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Lateral resolution in NALDI MSI: back to the future
Popis výsledku v původním jazyce
Nanostructure-assisted laser desorption/ionization (NALDI) has been recognized as a powerful matrix-free mass spectrometry tool ideal for imaging of small molecules. In this report, the NALDI approach was compared with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry in terms of sensitivity, reproducibility, and lateral resolution, which can be achieved in mass spectrometry imaging (MSI) experiments using a Nd:YAG laser. Scanning electron microscopy was used for surface topology analysis and evaluation of a putative surface-enhanced sensitivity effect, which was observed upon reduction of the laser focus. NALDI was identified as a more reproducible technique lacking MSI artifacts arising from distant tissue removal known from MALDI oversampling.
Název v anglickém jazyce
Lateral resolution in NALDI MSI: back to the future
Popis výsledku anglicky
Nanostructure-assisted laser desorption/ionization (NALDI) has been recognized as a powerful matrix-free mass spectrometry tool ideal for imaging of small molecules. In this report, the NALDI approach was compared with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry in terms of sensitivity, reproducibility, and lateral resolution, which can be achieved in mass spectrometry imaging (MSI) experiments using a Nd:YAG laser. Scanning electron microscopy was used for surface topology analysis and evaluation of a putative surface-enhanced sensitivity effect, which was observed upon reduction of the laser focus. NALDI was identified as a more reproducible technique lacking MSI artifacts arising from distant tissue removal known from MALDI oversampling.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F12%2F1150" target="_blank" >GAP206/12/1150: Vzorkování a účinnost desorpce/ionizace za atmosférického tlaku při hmotnostně spektrometrickém experimentu</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
407