Analysis of phosphodiesterase type 5 inhibitors as possible adulterants of botanical-based dietary supplements: extensive survey of preparations available at the Czech market
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F19%3A43918751" target="_blank" >RIV/60461373:22330/19:43918751 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0731708518311853?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0731708518311853?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jpba.2018.11.007" target="_blank" >10.1016/j.jpba.2018.11.007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of phosphodiesterase type 5 inhibitors as possible adulterants of botanical-based dietary supplements: extensive survey of preparations available at the Czech market
Popis výsledku v původním jazyce
Popularity of natural-based preparations supporting the sexual potency significantly increased in recent years, which also led to the increase of illegal use of phosphodiesterase type 5 inhibitor (PDE-5) in sexual performance enhancement products. In this study, a rapid U-HPLC‒HRMS/MS method has been developed to simultaneously determine 59 PDE-5 inhibitors and their analogues. Within the development of sensitive method for analysis of 59 PDE-5 inhibitors and their analogues, both sample preparation procedure, as well as separation / detection conditions have been optimized. Extraction efficiency of particular extraction solvents, influence of different mobile phase additives on target analytes separation, as well as impact of various settings of mass analyzer on sensitivity of detection were examined. Data were collected in the ‘full MS/data dependent MS/MS’ acquisition mode (full MS–dd-MS/MS). Before the U-HPLC‒HRMS/MS method was used for analysis of real samples, proper validation had been conducted. The precision of the method expressed as the relative standard deviation (RSD) was ≤4.2% and ≤5.2% at spiking concentrations 5 μg/g and 0.25 μg/g, respectively. The limits of quantification were in the range 0.25 – 0.05 μg/g and the recovery ranged between 71 and 90%. The optimized method was successfully applied for analysis of 64 real samples, and 10 of them were proved to contain both registered or unregistered synthetic PDE-5 inhibitors. Additionally, the acquired U-HPLC‒HRMS/MS fingerprints were demonstrated to serve as an efficient tool for revealing of other type of possible fraud in products labeling. Retrospective mining of markers of herbs declared on dietary supplements packaging allowed to assess the trueness / untruth in the declaration of medical herbs composition. © 2018 The Authors
Název v anglickém jazyce
Analysis of phosphodiesterase type 5 inhibitors as possible adulterants of botanical-based dietary supplements: extensive survey of preparations available at the Czech market
Popis výsledku anglicky
Popularity of natural-based preparations supporting the sexual potency significantly increased in recent years, which also led to the increase of illegal use of phosphodiesterase type 5 inhibitor (PDE-5) in sexual performance enhancement products. In this study, a rapid U-HPLC‒HRMS/MS method has been developed to simultaneously determine 59 PDE-5 inhibitors and their analogues. Within the development of sensitive method for analysis of 59 PDE-5 inhibitors and their analogues, both sample preparation procedure, as well as separation / detection conditions have been optimized. Extraction efficiency of particular extraction solvents, influence of different mobile phase additives on target analytes separation, as well as impact of various settings of mass analyzer on sensitivity of detection were examined. Data were collected in the ‘full MS/data dependent MS/MS’ acquisition mode (full MS–dd-MS/MS). Before the U-HPLC‒HRMS/MS method was used for analysis of real samples, proper validation had been conducted. The precision of the method expressed as the relative standard deviation (RSD) was ≤4.2% and ≤5.2% at spiking concentrations 5 μg/g and 0.25 μg/g, respectively. The limits of quantification were in the range 0.25 – 0.05 μg/g and the recovery ranged between 71 and 90%. The optimized method was successfully applied for analysis of 64 real samples, and 10 of them were proved to contain both registered or unregistered synthetic PDE-5 inhibitors. Additionally, the acquired U-HPLC‒HRMS/MS fingerprints were demonstrated to serve as an efficient tool for revealing of other type of possible fraud in products labeling. Retrospective mining of markers of herbs declared on dietary supplements packaging allowed to assess the trueness / untruth in the declaration of medical herbs composition. © 2018 The Authors
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Pharmaceutical and Biomedical Analysis
ISSN
0731-7085
e-ISSN
—
Svazek periodika
164
Číslo periodika v rámci svazku
FEB 2019
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
12
Strana od-do
713-724
Kód UT WoS článku
000456900700084
EID výsledku v databázi Scopus
2-s2.0-85056852792