Interlaboratory comparison investigations (ICI) and external quality assurance schemes (EQUAS) for cadmium in urine and blood: Results from the HBM4EU project
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F21%3A43922714" target="_blank" >RIV/60461373:22330/21:43922714 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1438463921000249?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1438463921000249?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijheh.2021.113711" target="_blank" >10.1016/j.ijheh.2021.113711</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Interlaboratory comparison investigations (ICI) and external quality assurance schemes (EQUAS) for cadmium in urine and blood: Results from the HBM4EU project
Popis výsledku v původním jazyce
Human biomonitoring (HBM) of cadmium is essential to assess and prevent toxic exposure. Generally, low cadmium levels in urine and blood of the general population place particularly high demands on quality assurance and control measures (QA/QC) for cadmium determination. One of the aims of the HBM4EU project is to harmonize and advance HBM in Europe. Cadmium is one of the chemicals selected as a priority substance for HBM implementation in the 30 European countries under HBM4EU. For this purpose, analytical comparability and accuracy of the analytical laboratories of participating countries was investigated in a QA/QC programme comprising interlaboratory comparison investigations (ICI) and external quality assurance schemes (EQUAS). This paper presents the evaluation process and discusses the results of four ICI/EQUAS rounds for the determination of cadmium in urine and blood. The majority of the 43 participating laboratories achieved satisfactory results, although low limits of quantification were required to quantify Cd concentrations at general population exposure levels. The relative standard deviation of the participants' results obtained from all ICI and EQUAS runs ranged from 8 to 36% for cadmium in urine and 8-28% for cadmium in blood. Applying inductively-coupled plasma mass spectrometry (ICP-MS), using an internal standard, and eliminating molybdenum oxide interferences was favourable for the accurate determination of cadmium in urine and blood. Furthermore, the analysis of cadmium in urine was found to have a critical point at approximately 0.05 μg/l, below which variability increased and laboratory proficiency decreased. This QA/QC programme succeeded in establishing a network of laboratories with high analytical comparability and accuracy for the analysis of cadmium across 20 European countries. Copyright © 2021 The Author(s). Published by Elsevier GmbH.. All rights reserved.
Název v anglickém jazyce
Interlaboratory comparison investigations (ICI) and external quality assurance schemes (EQUAS) for cadmium in urine and blood: Results from the HBM4EU project
Popis výsledku anglicky
Human biomonitoring (HBM) of cadmium is essential to assess and prevent toxic exposure. Generally, low cadmium levels in urine and blood of the general population place particularly high demands on quality assurance and control measures (QA/QC) for cadmium determination. One of the aims of the HBM4EU project is to harmonize and advance HBM in Europe. Cadmium is one of the chemicals selected as a priority substance for HBM implementation in the 30 European countries under HBM4EU. For this purpose, analytical comparability and accuracy of the analytical laboratories of participating countries was investigated in a QA/QC programme comprising interlaboratory comparison investigations (ICI) and external quality assurance schemes (EQUAS). This paper presents the evaluation process and discusses the results of four ICI/EQUAS rounds for the determination of cadmium in urine and blood. The majority of the 43 participating laboratories achieved satisfactory results, although low limits of quantification were required to quantify Cd concentrations at general population exposure levels. The relative standard deviation of the participants' results obtained from all ICI and EQUAS runs ranged from 8 to 36% for cadmium in urine and 8-28% for cadmium in blood. Applying inductively-coupled plasma mass spectrometry (ICP-MS), using an internal standard, and eliminating molybdenum oxide interferences was favourable for the accurate determination of cadmium in urine and blood. Furthermore, the analysis of cadmium in urine was found to have a critical point at approximately 0.05 μg/l, below which variability increased and laboratory proficiency decreased. This QA/QC programme succeeded in establishing a network of laboratories with high analytical comparability and accuracy for the analysis of cadmium across 20 European countries. Copyright © 2021 The Author(s). Published by Elsevier GmbH.. All rights reserved.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Hygiene and Environmental Health
ISSN
1438-4639
e-ISSN
—
Svazek periodika
234
Číslo periodika v rámci svazku
113711
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000648438200008
EID výsledku v databázi Scopus
2-s2.0-85103137710