Challenges in quality and safety analysis of fresh chili and powder thereof
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F25%3A43932428" target="_blank" >RIV/60461373:22330/25:43932428 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/abs/pii/S0021967325007678?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0021967325007678?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2025.466423" target="_blank" >10.1016/j.chroma.2025.466423</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Challenges in quality and safety analysis of fresh chili and powder thereof
Popis výsledku v původním jazyce
Chili peppers and chili products are ingredients used throughout the world. However, safety and quality concerns persist. This study established an ultra-high-performance liquid chromatography coupled with triple quadrupole mass spectrometry method for the simultaneous analysis of pesticide residues, mycotoxins, and major capsaicinoids (capsaicin, dihydrocapsaicin, nordihydrocapsaicin) in fresh chili peppers and chili powders. Chemical analysis of capsaicinoids using the Scoville Heat Unit was used to determine the pungency levels of the chilies. With this method, Czech retail chili samples were analyzed. Fresh chili and chili powder samples showed a wide range of pungency. This was connected with strong matrix effects in both fresh and powdered samples. Analytical challenges, especially in the zone of co-elution with the capsaicinoids, were overcome with dilution and standard addition. Additionally, samples from the Czech retail showed excessive pesticide residues as well, including three banned pesticides (carbofuran, chlorfluazuron, and chlorpyrifos). Mycotoxins were also found in chili powder exceeding the maximum limits, particularly ochratoxin A and aflatoxin B1. This method was also used to analyze imported fresh chili samples between the years 2022 to 2024. Pesticide residues exceeding maximum residue limits were found in 63.2 %, 84.2 %, and 11.2 % of analyzed samples each year. This study highlights the need for strict safety monitoring and effective analytical methods for chili products.
Název v anglickém jazyce
Challenges in quality and safety analysis of fresh chili and powder thereof
Popis výsledku anglicky
Chili peppers and chili products are ingredients used throughout the world. However, safety and quality concerns persist. This study established an ultra-high-performance liquid chromatography coupled with triple quadrupole mass spectrometry method for the simultaneous analysis of pesticide residues, mycotoxins, and major capsaicinoids (capsaicin, dihydrocapsaicin, nordihydrocapsaicin) in fresh chili peppers and chili powders. Chemical analysis of capsaicinoids using the Scoville Heat Unit was used to determine the pungency levels of the chilies. With this method, Czech retail chili samples were analyzed. Fresh chili and chili powder samples showed a wide range of pungency. This was connected with strong matrix effects in both fresh and powdered samples. Analytical challenges, especially in the zone of co-elution with the capsaicinoids, were overcome with dilution and standard addition. Additionally, samples from the Czech retail showed excessive pesticide residues as well, including three banned pesticides (carbofuran, chlorfluazuron, and chlorpyrifos). Mycotoxins were also found in chili powder exceeding the maximum limits, particularly ochratoxin A and aflatoxin B1. This method was also used to analyze imported fresh chili samples between the years 2022 to 2024. Pesticide residues exceeding maximum residue limits were found in 63.2 %, 84.2 %, and 11.2 % of analyzed samples each year. This study highlights the need for strict safety monitoring and effective analytical methods for chili products.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF CHROMATOGRAPHY A
ISSN
0021-9673
e-ISSN
1873-3778
Svazek periodika
1763
Číslo periodika v rámci svazku
466423
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
nestránkováno
Kód UT WoS článku
001596642500003
EID výsledku v databázi Scopus
2-s2.0-105017846175