Vapour pressure of phenanthrene and benzophenone was measured by Knudsen effusion method and by static method in the temperature range from 310 K to 373 K. Benzophenone is often used as a standard reference material for the measurement of vapour pressures. Phenanthrene is a typical polyaromatic hydrocarbon of interest for petroleum and coal processing industry.The effusion apparatus was used to measure vapour pressures of solids in the pressure range from 0.1 to 1 Pa. The static apparatus was redesignedand completely rebuilt to extend available temperature range and to improve accuracy and reproducibility of measured vapour pressures. Its available pressure range is from 1 Pa to 1300 Pa; this paper reports measurements from 1 Pa to 50 Pa. Inf1uence ofthermal transpiration in the static apparatus was examined experimentally.Recornmended vapour pressure data are given in terms of parameters of the Antoine and Cox vapour pressure correlation equations.
Název v anglickém jazyce
Vapour pressures of benzophhenone and phenathrene in tbe low-pressure region
Popis výsledku anglicky
Vapour pressure of phenanthrene and benzophenone was measured by Knudsen effusion method and by static method in the temperature range from 310 K to 373 K. Benzophenone is often used as a standard reference material for the measurement of vapour pressures. Phenanthrene is a typical polyaromatic hydrocarbon of interest for petroleum and coal processing industry.The effusion apparatus was used to measure vapour pressures of solids in the pressure range from 0.1 to 1 Pa. The static apparatus was redesignedand completely rebuilt to extend available temperature range and to improve accuracy and reproducibility of measured vapour pressures. Its available pressure range is from 1 Pa to 1300 Pa; this paper reports measurements from 1 Pa to 50 Pa. Inf1uence ofthermal transpiration in the static apparatus was examined experimentally.Recornmended vapour pressure data are given in terms of parameters of the Antoine and Cox vapour pressure correlation equations.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
Praha
Název nakladatele resp. objednatele
Česká společnost chemického inženýrství
Verze
neuveden
Identifikační číslo nosiče
1