Modeling of a Spatially Two-Dimensional Microchip for Immunoassay
Popis výsledku v původním jazyce
We have proposed a spatially two-dimensional model ofmicrochip for immunological determination of humanimmunoglobulin G (IgG) with the use of Protein A (PA)immobilized on the internal walls of a microchannel. Themicrochip consists of the central channelwith theimmobilized antigen and four channels for theintroduction of electrolytes. The convection flow in themicrodevice is induced by the imposed difference ofelectric potential (electroosmosis).We have analyzed the incubation phase of theimmunoassay. The effects of the antibody concentrationin a sample, the imposed difference of electric potential,and the surface heterogeneities in the reaction zone on thesaturation time have been studied. We have found that theincubation period of the quantitative immunoassay can becarried out within few minutes in the proposedmicrodevice, which enables fast diagnostics. Thecomputed calibration curve of the immunoassay is in agood agreement with the recently published experimentalresults.
Název v anglickém jazyce
Modeling of a Spatially Two-Dimensional Microchip for Immunoassay
Popis výsledku anglicky
We have proposed a spatially two-dimensional model ofmicrochip for immunological determination of humanimmunoglobulin G (IgG) with the use of Protein A (PA)immobilized on the internal walls of a microchannel. Themicrochip consists of the central channelwith theimmobilized antigen and four channels for theintroduction of electrolytes. The convection flow in themicrodevice is induced by the imposed difference ofelectric potential (electroosmosis).We have analyzed the incubation phase of theimmunoassay. The effects of the antibody concentrationin a sample, the imposed difference of electric potential,and the surface heterogeneities in the reaction zone on thesaturation time have been studied. We have found that theincubation period of the quantitative immunoassay can becarried out within few minutes in the proposedmicrodevice, which enables fast diagnostics. Thecomputed calibration curve of the immunoassay is in agood agreement with the recently published experimentalresults.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA104%2F02%2F0339" target="_blank" >GA104/02/0339: Nestacionární chování mikroreaktorů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
European Micro and Nano Systems EMN 2004, Paříž, Francie, 20.-21. 10. 2004, CD-ROM
ISBN
2-84813-037-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
esiee
Místo vydání
Paříž
Místo konání akce
Paříž
Datum konání akce
20. 10. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—