Sorpce metanolu a vody z kapalné i parní fáze v Nafionové membráně
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F06%3A00016704" target="_blank" >RIV/60461373:22340/06:00016704 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sorption of methanol and water in Nafion membrane from liquid and vapor phase
Popis výsledku v původním jazyce
Liquid and vapor phase sorption experiments of methanol and water and their mixtures in Nafion(R)112 membrane at temperature of 298.15 K were under study. The swelling measurements of systems pure water, pure methanol and methanol/water mixtures were carried out at temperature of 298.15 K and at atmospheric pressure. Membrane sample with size 5x5 mm was cut off from supply sheet and fixed by pike inside measuring Teflon cell. Whole cell with fixed sample was located into temperature-controlled oven. Swelling on Nafion in water is approximately three times lower than in methanol and maximal value of swelling was reached for methanol/water mixture containing 75 % of methanol. Vapor phase measurements were performed by gravimetric method and from experimental data the sorption isotherms were evaluated. Determined shape of methanol isotherm (3rd-order polynomial) is in agreement with literature. From knowledge of increments of membrane sample volume and density of pure methanol and water w
Název v anglickém jazyce
Sorption of methanol and water in Nafion membrane from liquid and vapor phase
Popis výsledku anglicky
Liquid and vapor phase sorption experiments of methanol and water and their mixtures in Nafion(R)112 membrane at temperature of 298.15 K were under study. The swelling measurements of systems pure water, pure methanol and methanol/water mixtures were carried out at temperature of 298.15 K and at atmospheric pressure. Membrane sample with size 5x5 mm was cut off from supply sheet and fixed by pike inside measuring Teflon cell. Whole cell with fixed sample was located into temperature-controlled oven. Swelling on Nafion in water is approximately three times lower than in methanol and maximal value of swelling was reached for methanol/water mixture containing 75 % of methanol. Vapor phase measurements were performed by gravimetric method and from experimental data the sorption isotherms were evaluated. Determined shape of methanol isotherm (3rd-order polynomial) is in agreement with literature. From knowledge of increments of membrane sample volume and density of pure methanol and water w
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník 17th International Congress of Chemical and Process Engineering
ISBN
80-86059-45-6
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
ČSCHI
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
27. 8. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce