Hustoty NaOH(aq) při teplotách od 323 K do 573 K.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F07%3A00019398" target="_blank" >RIV/60461373:22340/07:00019398 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Densities of NaOH(aq) at temperatures from 323 K to 573 K.
Popis výsledku v původním jazyce
Densities of sodium hydroxide solutions at concentrations 0.1 m/mol kg 8 have been measured by vibrating-tube densimetry over the temperature range 323 T/K 573 at a pressure of 10 MPa. The purpose-built densimeter, which is capable of measuring densitiesof corrosive fluids at temperatures up to 573 K and pressures up to 30 MPa, has a platinum-rhodium vibrating tube with inlet/outlet tubes of platinum and an optical detection system. Calibrations were carried out with water and aqueous solutions of sodium chloride at temperatures up to 523 K. At higher temperatures, nitrogen was substituted as the auxiliary density reference because of uncertainties in the NaCl(aq) densities. The apparent molar volumes of NaOH(aq) calculated from the measured densitieswere fitted with an extended Redlich-Meyer equation. The present results are in good agreement with literature data but are more precise. The current global accuracy in the densities of NaOH(aq) appears to be about 0.1 %, being better at
Název v anglickém jazyce
Densities of NaOH(aq) at temperatures from 323 K to 573 K.
Popis výsledku anglicky
Densities of sodium hydroxide solutions at concentrations 0.1 m/mol kg 8 have been measured by vibrating-tube densimetry over the temperature range 323 T/K 573 at a pressure of 10 MPa. The purpose-built densimeter, which is capable of measuring densitiesof corrosive fluids at temperatures up to 573 K and pressures up to 30 MPa, has a platinum-rhodium vibrating tube with inlet/outlet tubes of platinum and an optical detection system. Calibrations were carried out with water and aqueous solutions of sodium chloride at temperatures up to 523 K. At higher temperatures, nitrogen was substituted as the auxiliary density reference because of uncertainties in the NaCl(aq) densities. The apparent molar volumes of NaOH(aq) calculated from the measured densitieswere fitted with an extended Redlich-Meyer equation. The present results are in good agreement with literature data but are more precise. The current global accuracy in the densities of NaOH(aq) appears to be about 0.1 %, being better at
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chemical Engineering Data
ISSN
0021-9568
e-ISSN
—
Svazek periodika
52
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
2237-2244
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—