LIF microfluidic system for immunoanalytical detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F10%3A00023215" target="_blank" >RIV/60461373:22340/10:00023215 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LIF microfluidic system for immunoanalytical detection
Popis výsledku v původním jazyce
Multichannel microfluidic chips with laser induced fluorescence (LIF) detection apparatus intended for detection of protein markers are presented in this work. The microfluidic chips are fabricated from PDMS by a combination of UV photolithography, casting, thermal bonding etc. Fluorescence detection of bioaffinity complexes in microchannels is carried out by sensitive detection system. For the fabrication of the microfluidic devices we have developed a unique fabrication technique based on PDMS castingagainst phosphore bronze substrate with SU-8 structures on the surface. Sensitive detection is achieved by the complex laser-based detection apparatus. This detection system is composed of a laser exciting source, optical fibers, reflexing probe, optical filter, PMT, step motors, measuring elements and computer. Laser beam is guided from laser source by optical fibers to reflexive probe beyond microfluidic device. The movement of the microfluidic device is provided by two computer contr
Název v anglickém jazyce
LIF microfluidic system for immunoanalytical detection
Popis výsledku anglicky
Multichannel microfluidic chips with laser induced fluorescence (LIF) detection apparatus intended for detection of protein markers are presented in this work. The microfluidic chips are fabricated from PDMS by a combination of UV photolithography, casting, thermal bonding etc. Fluorescence detection of bioaffinity complexes in microchannels is carried out by sensitive detection system. For the fabrication of the microfluidic devices we have developed a unique fabrication technique based on PDMS castingagainst phosphore bronze substrate with SU-8 structures on the surface. Sensitive detection is achieved by the complex laser-based detection apparatus. This detection system is composed of a laser exciting source, optical fibers, reflexing probe, optical filter, PMT, step motors, measuring elements and computer. Laser beam is guided from laser source by optical fibers to reflexive probe beyond microfluidic device. The movement of the microfluidic device is provided by two computer contr
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 37th International Conference of Slovak Society of Chemical Engineering, 2010
ISBN
978-80-227-3290-1
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Slovak Society of Chemical Engineering
Místo vydání
Bratislava
Místo konání akce
Tatranské Matliare, Slovakia
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—