Digital Processing of Experimental Data Obtained During Gravimetric Sorption Experiments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F11%3A43892145" target="_blank" >RIV/60461373:22340/11:43892145 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Digital Processing of Experimental Data Obtained During Gravimetric Sorption Experiments
Popis výsledku v původním jazyce
Experimental data obtained during gravimetric sorption experiments include noise caused by the fact that at the beginning of sorption experiment introducing of determined amount of vapours from gas reservoir into evacuated measuring chamber leads to spurious oscillations of the spiral balance. Noise causes that optimization methods for integral diffusion coefficient determination do not converge. Complex program in Matlab was developed in order to remove noise from experimental data and to determine value of diffusion coefficient. The main goals of data processing are more accurate determination of diffusion coefficient, quicker computation and facilitation and automation of calculation. Correct operation of algorithm was verified at processing of experimental data obtained during the sorption of organic vapours in flat polymer samples. The vapour sorption experiments are performed gravimetrically by the sorption apparatus equipped with the calibrated quartz (McBain's) spiral balance.
Název v anglickém jazyce
Digital Processing of Experimental Data Obtained During Gravimetric Sorption Experiments
Popis výsledku anglicky
Experimental data obtained during gravimetric sorption experiments include noise caused by the fact that at the beginning of sorption experiment introducing of determined amount of vapours from gas reservoir into evacuated measuring chamber leads to spurious oscillations of the spiral balance. Noise causes that optimization methods for integral diffusion coefficient determination do not converge. Complex program in Matlab was developed in order to remove noise from experimental data and to determine value of diffusion coefficient. The main goals of data processing are more accurate determination of diffusion coefficient, quicker computation and facilitation and automation of calculation. Correct operation of algorithm was verified at processing of experimental data obtained during the sorption of organic vapours in flat polymer samples. The vapour sorption experiments are performed gravimetrically by the sorption apparatus equipped with the calibrated quartz (McBain's) spiral balance.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
38th International Conference of Slovak Society of Chemical Engineering
ISBN
978-80-227-3503-2
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
412-421
Název nakladatele
Slovak Society of Chemical Engineering
Místo vydání
Bratislava
Místo konání akce
Tatranské Matliare, Vysoké Tatry, Slovakia
Datum konání akce
23. 5. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—