Complexometry with EDTA as a quality control tool for certified single-element aqueous standard solutions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F13%3A43895614" target="_blank" >RIV/60461373:22340/13:43895614 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00769-013-1010-y" target="_blank" >http://dx.doi.org/10.1007/s00769-013-1010-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00769-013-1010-y" target="_blank" >10.1007/s00769-013-1010-y</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Complexometry with EDTA as a quality control tool for certified single-element aqueous standard solutions
Popis výsledku v původním jazyce
The capability of complexometric EDTA titrimetry to determine the nominal concentration of the analyte in aqueous single-element standard solutions with an expected expanded uncertainty U of { 0.2 % is investigated. A calibration solutions Astasol(A (R))and a standard solutions from internationally recognized producers are tested. The results covering about 40 analytes show that EDTA titrations can be effectively employed for this purpose. Nominal concentrations and their uncertainties are calculated by using numerical Kragten spreadsheets. The metrological traceability of the results is realized through NIST SRM 928 (lead nitrate), which is used for the standardization of the EDTA.
Název v anglickém jazyce
Complexometry with EDTA as a quality control tool for certified single-element aqueous standard solutions
Popis výsledku anglicky
The capability of complexometric EDTA titrimetry to determine the nominal concentration of the analyte in aqueous single-element standard solutions with an expected expanded uncertainty U of { 0.2 % is investigated. A calibration solutions Astasol(A (R))and a standard solutions from internationally recognized producers are tested. The results covering about 40 analytes show that EDTA titrations can be effectively employed for this purpose. Nominal concentrations and their uncertainties are calculated by using numerical Kragten spreadsheets. The metrological traceability of the results is realized through NIST SRM 928 (lead nitrate), which is used for the standardization of the EDTA.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Accreditation and Quality Assurance
ISSN
0949-1775
e-ISSN
—
Svazek periodika
18
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
491-499
Kód UT WoS článku
000327853700005
EID výsledku v databázi Scopus
—