X-ray Tomography Imaging of Porous Polyolefin Particles in an Electron Microscope
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F13%3A43895650" target="_blank" >RIV/60461373:22340/13:43895650 - isvavai.cz</a>
Výsledek na webu
<a href="http://onlinelibrary.wiley.com/doi/10.1002/mren.201300002/abstract" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/mren.201300002/abstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/mren.201300002" target="_blank" >10.1002/mren.201300002</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
X-ray Tomography Imaging of Porous Polyolefin Particles in an Electron Microscope
Popis výsledku v původním jazyce
Advanced models of penetrant transport and reaction in spatially three-dimensional porous polyolefin particles reconstructed from X-ray micro-tomography (micro CT) images require proper determination of particle morphology otherwise the models cannot bevalidated by experimental data. Moreover, polyolefins exhibit a relatively low absorptivity for X-rays, therefore their investigation using micro CT can be difficult. In this paper, we utilize a low-resolution micro CT built-in a scanning electron microscope (SEM) and examine how the micro CT resolution and several user-selected parameters associated with the scanning/reconstruction affect the resulting particle morphology. Using samples with known morphology and independent imaging techniques (SEM) wecritically assess the performance of the micro CT device. Finally, we propose a methodology suitable for the reliable reconstruction of polyolefin particles using low-resolution micro CT.
Název v anglickém jazyce
X-ray Tomography Imaging of Porous Polyolefin Particles in an Electron Microscope
Popis výsledku anglicky
Advanced models of penetrant transport and reaction in spatially three-dimensional porous polyolefin particles reconstructed from X-ray micro-tomography (micro CT) images require proper determination of particle morphology otherwise the models cannot bevalidated by experimental data. Moreover, polyolefins exhibit a relatively low absorptivity for X-rays, therefore their investigation using micro CT can be difficult. In this paper, we utilize a low-resolution micro CT built-in a scanning electron microscope (SEM) and examine how the micro CT resolution and several user-selected parameters associated with the scanning/reconstruction affect the resulting particle morphology. Using samples with known morphology and independent imaging techniques (SEM) wecritically assess the performance of the micro CT device. Finally, we propose a methodology suitable for the reliable reconstruction of polyolefin particles using low-resolution micro CT.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP106%2F10%2F1912" target="_blank" >GAP106/10/1912: Morfologií ovlivněná sorpce a difuze penetrantů v polymerech</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Macromolecular Reaction Engineering
ISSN
1862-8338
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
277-288
Kód UT WoS článku
000320556700004
EID výsledku v databázi Scopus
—