Simple spectrophotometric method for determination of polyvinylalcohol in different types of wastewater
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F14%3A43895430" target="_blank" >RIV/60461373:22340/14:43895430 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60461373:22320/14:43895430
Výsledek na webu
<a href="http://dx.doi.org/10.1080/03067319.2013.853761" target="_blank" >http://dx.doi.org/10.1080/03067319.2013.853761</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/03067319.2013.853761" target="_blank" >10.1080/03067319.2013.853761</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simple spectrophotometric method for determination of polyvinylalcohol in different types of wastewater
Popis výsledku v původním jazyce
The determination of polyvinylalcohol (PVA) by the formation of the blue iodine-PVA complex method was established for a semi-micro method scale. The direct addition of iodine solution proved to be a better iodine source than iodine generated in situ. The ageing of reagents requires frequent calibrations. Common biopolymers such as starch, albumin and cellulose produced much lower colour intensity with reagents and their impact on the analysis is negligible. The method is not affected by paper filter filtration. The detection of PVA was successfully tested in different wastewater types and the method proved to be a powerful tool for PVA detection. It must be emphasised that quantification of PVA is strongly dependent on the PVA type and the quantification capacity; without information of the PVA structure or type is only tentative
Název v anglickém jazyce
Simple spectrophotometric method for determination of polyvinylalcohol in different types of wastewater
Popis výsledku anglicky
The determination of polyvinylalcohol (PVA) by the formation of the blue iodine-PVA complex method was established for a semi-micro method scale. The direct addition of iodine solution proved to be a better iodine source than iodine generated in situ. The ageing of reagents requires frequent calibrations. Common biopolymers such as starch, albumin and cellulose produced much lower colour intensity with reagents and their impact on the analysis is negligible. The method is not affected by paper filter filtration. The detection of PVA was successfully tested in different wastewater types and the method proved to be a powerful tool for PVA detection. It must be emphasised that quantification of PVA is strongly dependent on the PVA type and the quantification capacity; without information of the PVA structure or type is only tentative
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental Analytical Chemistry
ISSN
0306-7319
e-ISSN
—
Svazek periodika
94
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
399-410