Traveling wave electroosmosis: The influence of electrode array geometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F14%3A43897992" target="_blank" >RIV/60461373:22340/14:43897992 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/elps.201300614" target="_blank" >http://dx.doi.org/10.1002/elps.201300614</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.201300614" target="_blank" >10.1002/elps.201300614</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Traveling wave electroosmosis: The influence of electrode array geometry
Popis výsledku v původním jazyce
We used a mathematical model describing traveling-wave electroosmotic micropumps to explain their rather poor ability to work against pressure loads. The mathematical model is based upon the Poisson-Nernst-Planck-Navier-Stokes approach, that is, a directnumerical simulation, which allows a detail study of the energy transformations and the charging dynamics of the electric double layers. Using Matlab and COMSOL Multiphysics, we performed a set of extensive parametric studies to determine the dependenceof generated electroosmotic flow on the geometric arrangement of the pump. The results suggest that the performance of AC electroosmotic pumps should improve with miniaturization. The AC electroosmosis is likely to be suitable only at submicrometer scale, as the pump's ability to work against pressure load diminishes rapidly when increasing the channel diameter.
Název v anglickém jazyce
Traveling wave electroosmosis: The influence of electrode array geometry
Popis výsledku anglicky
We used a mathematical model describing traveling-wave electroosmotic micropumps to explain their rather poor ability to work against pressure loads. The mathematical model is based upon the Poisson-Nernst-Planck-Navier-Stokes approach, that is, a directnumerical simulation, which allows a detail study of the energy transformations and the charging dynamics of the electric double layers. Using Matlab and COMSOL Multiphysics, we performed a set of extensive parametric studies to determine the dependenceof generated electroosmotic flow on the geometric arrangement of the pump. The results suggest that the performance of AC electroosmotic pumps should improve with miniaturization. The AC electroosmosis is likely to be suitable only at submicrometer scale, as the pump's ability to work against pressure load diminishes rapidly when increasing the channel diameter.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA01010353" target="_blank" >TA01010353: Recyklace, separace a rafinace vzácných kovů (indium, gallium, ...) z druhotných surovin elektronického a fotovoltaického průmyslu</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
12-13
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
1790-1794
Kód UT WoS článku
000339015000006
EID výsledku v databázi Scopus
—