Analogy of Mass Transfer in Absorption and Distillation Columns: Wetted Wall Column Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F15%3A43900302" target="_blank" >RIV/60461373:22340/15:43900302 - isvavai.cz</a>
Výsledek na webu
<a href="http://www3.aiche.org/proceedings/Conference.aspx?ConfID=Spring-GCPS-2015" target="_blank" >http://www3.aiche.org/proceedings/Conference.aspx?ConfID=Spring-GCPS-2015</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analogy of Mass Transfer in Absorption and Distillation Columns: Wetted Wall Column Study
Popis výsledku v původním jazyce
The prediction of the packing mass transfer efficiency under distillation conditions out of the absorption data provides results which can be unreliable even if the absorption data are measured using proved systems. This discrepancy can be accounted forthe influence of the phase hydrodynamic, different formation of the effective interfacial area or generally unreliable transfer of the mass-transfer coefficients between the distillation and absorption. This study is focused on the analogy of the mass transfer in absorption and distillation columns. The wetted wall column was chosen as the experimental device for this study as it provides identical interfacial area for both, absorption and distillation processes eliminating its influence on the mass transfer. Although there are a lot of papers dealing with the mass transfer characteristics of the wetted wall column, there is only a limited amount of the literature data measured on the absorption systems under the conditions similar to t
Název v anglickém jazyce
Analogy of Mass Transfer in Absorption and Distillation Columns: Wetted Wall Column Study
Popis výsledku anglicky
The prediction of the packing mass transfer efficiency under distillation conditions out of the absorption data provides results which can be unreliable even if the absorption data are measured using proved systems. This discrepancy can be accounted forthe influence of the phase hydrodynamic, different formation of the effective interfacial area or generally unreliable transfer of the mass-transfer coefficients between the distillation and absorption. This study is focused on the analogy of the mass transfer in absorption and distillation columns. The wetted wall column was chosen as the experimental device for this study as it provides identical interfacial area for both, absorption and distillation processes eliminating its influence on the mass transfer. Although there are a lot of papers dealing with the mass transfer characteristics of the wetted wall column, there is only a limited amount of the literature data measured on the absorption systems under the conditions similar to t
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-01251S" target="_blank" >GA13-01251S: Experimentální ověření rychlostního návrhu destilačních kolon založená na transportních koeficientech měřených přímo v destilační koloně</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of AICHE Spring Meeting and 11th Global Congress on Process Safety
ISBN
978-0-8169-1089-2
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1-7
Název nakladatele
American Institute of Chemical Engineers (AIChE)
Místo vydání
New York
Místo konání akce
Austin
Datum konání akce
26. 4. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—