Electrochemical Detection of Sialic Acid Using Phenylboronic Acid-Modified Poly (Diaminobenzoic Acid) Electrodes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F18%3A43915442" target="_blank" >RIV/60461373:22340/18:43915442 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388963:_____/18:00489957 RIV/00216208:11110/18:10376682
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/abs/10.1002/elan.201700634" target="_blank" >https://onlinelibrary.wiley.com/doi/abs/10.1002/elan.201700634</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201700634" target="_blank" >10.1002/elan.201700634</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Detection of Sialic Acid Using Phenylboronic Acid-Modified Poly (Diaminobenzoic Acid) Electrodes
Popis výsledku v původním jazyce
This study is focused on the electrochemical detection of sialic acid (SA) using electrochemical impedance spectroscopy (EIS) and potentiometric approaches with the polymeric film derived from 3,4-diaminobenzoic acid (3,4-DABA) and modified with 3-aminophenylboronic acid (3-APBA). The polymeric film derived from 3,4-DABA was prepared using cyclic voltammetry at 0.5 M H2SO4 on a platinum disc electrode from 0 to 1.20 V vs. Ag/AgCl and characterized by FTIR-Raman spectroscopy. It has been found that the polymerization process goes through the amino group and a free carboxyl group serves for the covalent binding of 3-APBA onto the polymeric backbone. Both the electrochemical approaches independently confirmed the recognition of SA by APBA-modified PDABA electrodes. In contrast to known electrochemical sensors in the literature, the APBA-modified PADABA sensor for SA gave a response in the range from 0.025 to 0.998 mM at neutral pH using the EIS method. The decrease in the EIS signal of ca 12 % was observed after two weeks of intensive use. Importantly, the selective APBA-modified polymeric electrode enabled the use of SA determination in artificial urine samples in a concentration range that is useful for diagnostic purposes, specifically 12–102 μg mL−1.
Název v anglickém jazyce
Electrochemical Detection of Sialic Acid Using Phenylboronic Acid-Modified Poly (Diaminobenzoic Acid) Electrodes
Popis výsledku anglicky
This study is focused on the electrochemical detection of sialic acid (SA) using electrochemical impedance spectroscopy (EIS) and potentiometric approaches with the polymeric film derived from 3,4-diaminobenzoic acid (3,4-DABA) and modified with 3-aminophenylboronic acid (3-APBA). The polymeric film derived from 3,4-DABA was prepared using cyclic voltammetry at 0.5 M H2SO4 on a platinum disc electrode from 0 to 1.20 V vs. Ag/AgCl and characterized by FTIR-Raman spectroscopy. It has been found that the polymerization process goes through the amino group and a free carboxyl group serves for the covalent binding of 3-APBA onto the polymeric backbone. Both the electrochemical approaches independently confirmed the recognition of SA by APBA-modified PDABA electrodes. In contrast to known electrochemical sensors in the literature, the APBA-modified PADABA sensor for SA gave a response in the range from 0.025 to 0.998 mM at neutral pH using the EIS method. The decrease in the EIS signal of ca 12 % was observed after two weeks of intensive use. Importantly, the selective APBA-modified polymeric electrode enabled the use of SA determination in artificial urine samples in a concentration range that is useful for diagnostic purposes, specifically 12–102 μg mL−1.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
9
Strana od-do
672-680
Kód UT WoS článku
000429708900013
EID výsledku v databázi Scopus
2-s2.0-85037999868