The accuracy of kLa evaluation at various transient rates of oxygen probe
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F21%3A43923781" target="_blank" >RIV/60461373:22340/21:43923781 - isvavai.cz</a>
Výsledek na webu
<a href="http://sschi.chtf.stuba.sk/data/papers/326.pdf" target="_blank" >http://sschi.chtf.stuba.sk/data/papers/326.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The accuracy of kLa evaluation at various transient rates of oxygen probe
Popis výsledku v původním jazyce
Mass controlled-processes are crucial for the most of products in chemical and similar industries. The volumetric mass transfer coefficient, kLa, becomes the indispensable parameter, for these processes with the gas-liquid mass transfer rate as the controlling factor. At the moment the volumetric mass transfer coefficient is usually predicted on the base of literature correlations. However, the many of correlations have their limits due to way how it should not be able predict kLa in other design of vessel then it was measured. Due to fact of their principle how to characterise vessels or ratio between diameters of vessel and impeller. Despite this fact, the correlation created by the dynamic pressure method was demonstrated to be physically correct in past in many operating conditions and for many types of batches. One of the key parameter for accurate value of kLa is dependence on the attribute of oxygen optical probe, transient rate (time response) ????M.
Název v anglickém jazyce
The accuracy of kLa evaluation at various transient rates of oxygen probe
Popis výsledku anglicky
Mass controlled-processes are crucial for the most of products in chemical and similar industries. The volumetric mass transfer coefficient, kLa, becomes the indispensable parameter, for these processes with the gas-liquid mass transfer rate as the controlling factor. At the moment the volumetric mass transfer coefficient is usually predicted on the base of literature correlations. However, the many of correlations have their limits due to way how it should not be able predict kLa in other design of vessel then it was measured. Due to fact of their principle how to characterise vessels or ratio between diameters of vessel and impeller. Despite this fact, the correlation created by the dynamic pressure method was demonstrated to be physically correct in past in many operating conditions and for many types of batches. One of the key parameter for accurate value of kLa is dependence on the attribute of oxygen optical probe, transient rate (time response) ????M.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20401 - Chemical engineering (plants, products)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PROCEEDINGS 47th International Conference of the Slovak Society of Chemical Engineering
ISBN
978-80-8208-057-8
ISSN
—
e-ISSN
—
Počet stran výsledku
11
Strana od-do
1-11
Název nakladatele
Vydavateľstvo STU v Bratislave
Místo vydání
Bratislava
Místo konání akce
Bratislava
Datum konání akce
18. 5. 2021
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—