Screening of Synthetic Cathinones by Potentiometric Sensor Array and Chemometrics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F22%3A43922499" target="_blank" >RIV/60461373:22340/22:43922499 - isvavai.cz</a>
Výsledek na webu
<a href="https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elan.202100483" target="_blank" >https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elan.202100483</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.202100483" target="_blank" >10.1002/elan.202100483</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Screening of Synthetic Cathinones by Potentiometric Sensor Array and Chemometrics
Popis výsledku v původním jazyce
This work demonstrates the analytical applicability of single ion-selective membranes (ISMs) and potentiometric sensor array to distinguish and detect cathinone derivatives. Potentiometric data from ISMs based on cation exchanger and varying content of calix[4]arene derivative were processed by principal component analysis (PCA). Such a combination of methods allowed discriminating various individual synthetic cathinones and their recognition from the mixture comprising primary amines (substituted amphetamines+ aminoindane). Analytical parameters of ISM containing 1wt % of calix[4]arene derivative were sufficient to detect 1.0×10???? 4 mol.l???? 1 1-(4-fluorophenyl)-2-(ethylamino)butan- 1-one and 2-(methylamino)-1-phenylbutan-1-one (buphedrone) in both model and saliva samples.
Název v anglickém jazyce
Screening of Synthetic Cathinones by Potentiometric Sensor Array and Chemometrics
Popis výsledku anglicky
This work demonstrates the analytical applicability of single ion-selective membranes (ISMs) and potentiometric sensor array to distinguish and detect cathinone derivatives. Potentiometric data from ISMs based on cation exchanger and varying content of calix[4]arene derivative were processed by principal component analysis (PCA). Such a combination of methods allowed discriminating various individual synthetic cathinones and their recognition from the mixture comprising primary amines (substituted amphetamines+ aminoindane). Analytical parameters of ISM containing 1wt % of calix[4]arene derivative were sufficient to detect 1.0×10???? 4 mol.l???? 1 1-(4-fluorophenyl)-2-(ethylamino)butan- 1-one and 2-(methylamino)-1-phenylbutan-1-one (buphedrone) in both model and saliva samples.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
1521-4109
Svazek periodika
34
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
1193-1200
Kód UT WoS článku
000742058700001
EID výsledku v databázi Scopus
2-s2.0-85122803608