3D stereolithography print (SLA) in clinical orthodontic and dental applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F22%3A43924628" target="_blank" >RIV/60461373:22340/22:43924628 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064203:_____/22:10444551 RIV/00216208:11130/22:10444551 RIV/00216224:14310/22:00125488
Výsledek na webu
<a href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11942/2608661/3D-stereolithography-print-SLA-in-clinical-orthodontic-and-dental-applications/10.1117/12.2608661.short" target="_blank" >https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11942/2608661/3D-stereolithography-print-SLA-in-clinical-orthodontic-and-dental-applications/10.1117/12.2608661.short</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.2608661" target="_blank" >10.1117/12.2608661</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
3D stereolithography print (SLA) in clinical orthodontic and dental applications
Popis výsledku v původním jazyce
The aim of our study was 3D objectification of stereolithography prepared printed models. Patients during clinical treatment were scanned by an optical scanner. Data from scanner were transferred to the STL files and then stereolithographic models were prepared. Method of optical triangulation, photogrammetric methods and mathematical model analysis were used for measurements. The surface profile was also evaluated. After three years, the quality of STL models was smooth and homogeneous and it was directly connected with the type and structure of filaments. Clinical applications demonstrated also treatment options for patients with nausea, rare diseases, or with small space between upper and lower jaw.
Název v anglickém jazyce
3D stereolithography print (SLA) in clinical orthodontic and dental applications
Popis výsledku anglicky
The aim of our study was 3D objectification of stereolithography prepared printed models. Patients during clinical treatment were scanned by an optical scanner. Data from scanner were transferred to the STL files and then stereolithographic models were prepared. Method of optical triangulation, photogrammetric methods and mathematical model analysis were used for measurements. The surface profile was also evaluated. After three years, the quality of STL models was smooth and homogeneous and it was directly connected with the type and structure of filaments. Clinical applications demonstrated also treatment options for patients with nausea, rare diseases, or with small space between upper and lower jaw.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Lasers in Dentistry XXVIII, Proceedings of SPIE Volume 11942
ISBN
978-1-5106-4755-8
ISSN
1605-7422
e-ISSN
2410-9045
Počet stran výsledku
7
Strana od-do
"1194207:1"-"1194207:7"
Název nakladatele
SPIE
Místo vydání
Bellingham, Washington
Místo konání akce
San Francisco
Datum konání akce
23. 1. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000825395000006