Energy Sensitive X-r ay Radiography for the Non-destructive Inspection of Historical Paintings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461446%3A52810%2F10%3A%230000079" target="_blank" >RIV/60461446:52810/10:#0000079 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388980:_____/10:00375811 RIV/68407700:21670/10:00226201
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Energy Sensitive X-r ay Radiography for the Non-destructive Inspection of Historical Paintings
Popis výsledku v původním jazyce
Transmission and emission non-invasive analytical methods based on the interaction of ionizing radiation with the matter have been successfully utilized during the last decades. The presently used detectors (CCD cameras and CMOS sensors) create the imagefrom analogue signal by charge integration. The image is usually degraded by the presence of noise. Noise is exceeded by novel pixel detectors of Medipix family based on single part digital counting. These devices also offer very high contrast in the obtained image. Another advantage of these detectors is their ability to directly measure the energy of incident particles. This feature can be used for energy sensitive X-ray radiography (i.e. multi-channel images) and X-ray fluorescence mapping of the surface elemental composition. For the purposes of this work several multilayer samples of paints using different pigments were prepared. Results of mentioned methods applied on the test samples are summarized in this article.
Název v anglickém jazyce
Energy Sensitive X-r ay Radiography for the Non-destructive Inspection of Historical Paintings
Popis výsledku anglicky
Transmission and emission non-invasive analytical methods based on the interaction of ionizing radiation with the matter have been successfully utilized during the last decades. The presently used detectors (CCD cameras and CMOS sensors) create the imagefrom analogue signal by charge integration. The image is usually degraded by the presence of noise. Noise is exceeded by novel pixel detectors of Medipix family based on single part digital counting. These devices also offer very high contrast in the obtained image. Another advantage of these detectors is their ability to directly measure the energy of incident particles. This feature can be used for energy sensitive X-ray radiography (i.e. multi-channel images) and X-ray fluorescence mapping of the surface elemental composition. For the purposes of this work several multilayer samples of paints using different pigments were prepared. Results of mentioned methods applied on the test samples are summarized in this article.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LC06041" target="_blank" >LC06041: Příprava, modifikace a charakterizace materiálů energetickým zářením</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ACTA ARTIS ACADEMICA 2010 : THE STORY OF ART - ARTWORK CHANGES IN TIME
ISBN
978-80-87108-14-7
ISSN
—
e-ISSN
—
Počet stran výsledku
11
Strana od-do
—
Název nakladatele
Akademie výtvarných umění, Praha
Místo vydání
Prague, Czech Republic
Místo konání akce
Prague
Datum konání akce
1. 1. 2010
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000288141200018