Detekce stenózy karotid Dopplerovskou ultrasonografií - porovnání histopatologických nálezů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F07%3A16" target="_blank" >RIV/61383082:_____/07:16 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Doppler ultrasonography in the detection of carotid stenosis - comparision to histopathological findings
Popis výsledku v původním jazyce
Prospective study was performed comparing the accuracy of Doppler ultrasonography (DUS) stenosis findings with measurements on histological specimens. Method: DUS were used to evaluate carotid stenosis and were compared to measurements on histological specimens. Intact carotid plaques from 123 cases were removed in one piece during surgery. The specimens were histologically processed and transversally cut. The smallest inner and correlating outer diameters were measured and the extent of stenosis was calculated. Carotid artery stenoses were compared and statistics done. DUS seems to be accurate in classifying stenoses into different groups in the extent of narrowing of the carotid arteries. Nevertheless, in absolute numbers significant differences werefound.
Název v anglickém jazyce
Doppler ultrasonography in the detection of carotid stenosis - comparision to histopathological findings
Popis výsledku anglicky
Prospective study was performed comparing the accuracy of Doppler ultrasonography (DUS) stenosis findings with measurements on histological specimens. Method: DUS were used to evaluate carotid stenosis and were compared to measurements on histological specimens. Intact carotid plaques from 123 cases were removed in one piece during surgery. The specimens were histologically processed and transversally cut. The smallest inner and correlating outer diameters were measured and the extent of stenosis was calculated. Carotid artery stenoses were compared and statistics done. DUS seems to be accurate in classifying stenoses into different groups in the extent of narrowing of the carotid arteries. Nevertheless, in absolute numbers significant differences werefound.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FH - Neurologie, neurochirurgie, neurovědy
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR9435" target="_blank" >NR9435: Korelace MR angiografie, dopplerovské ultrasonografie a digitální subtrakční angiografie s histologickými nálezy stenózy krkavice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Doppler ultrasonography in the detection of carotid stenosis - comparision to histopathological findings
ISBN
978-88-7587-386-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
533-536
Název nakladatele
Monduzzi Editore
Místo vydání
Itálie
Místo konání akce
Velká Británie, Glasgow
Datum konání akce
1. 1. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—