Factors underlying elevated troponin I levels following pacemaker primo-implantation.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F16%3A00000117" target="_blank" >RIV/61383082:_____/16:00000117 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/16:00091492 RIV/00216208:11110/16:10327372 RIV/61989592:15110/17:73582226
Výsledek na webu
<a href="http://biomed.papers.upol.cz/artkey/bio-201602-0011_Factors_underlying_elevated_troponin_I_levels_following_pacemaker_primo-implantation.php" target="_blank" >http://biomed.papers.upol.cz/artkey/bio-201602-0011_Factors_underlying_elevated_troponin_I_levels_following_pacemaker_primo-implantation.php</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2015.067" target="_blank" >10.5507/bp.2015.067</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Factors underlying elevated troponin I levels following pacemaker primo-implantation.
Popis výsledku v původním jazyce
Background. Cardiac troponins are routinely used as markers of myocardial damage. Originally, they were only intended for use in diagnosing acute coronary syndromes; however, we now know that raised serum troponin levels are not always caused by ischemia. There are many other clinical conditions that cause damage to cardiomyocytes, leading to raised levels of troponin. However, the specificity of cardiac troponins towards the myocardium is absolute. Our work focuses on mechanical damage to the myocardium and on monitoring the factors that raise the levels of cardiospecific markers after primo-implantation of a pacemaker with an actively fixed electrode.
Název v anglickém jazyce
Factors underlying elevated troponin I levels following pacemaker primo-implantation.
Popis výsledku anglicky
Background. Cardiac troponins are routinely used as markers of myocardial damage. Originally, they were only intended for use in diagnosing acute coronary syndromes; however, we now know that raised serum troponin levels are not always caused by ischemia. There are many other clinical conditions that cause damage to cardiomyocytes, leading to raised levels of troponin. However, the specificity of cardiac troponins towards the myocardium is absolute. Our work focuses on mechanical damage to the myocardium and on monitoring the factors that raise the levels of cardiospecific markers after primo-implantation of a pacemaker with an actively fixed electrode.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FE - Ostatní obory vnitřního lékařství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BIOMEDICAL PAPERS-OLOMOUC
ISSN
1213-8118
e-ISSN
—
Svazek periodika
160
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
248-256
Kód UT WoS článku
000379360500011
EID výsledku v databázi Scopus
—