Measurement of displacement of percutaneous lead for spinal cord stimulation
Popis výsledku v původním jazyce
A Medtronic implantable neurostimulation system is indicated for spinal cord stimulation (SCS) as an aid in the management of chronic, intractable pain of the trunk and limbs. The method of anchors fixing may have a significant influence on the elimination or reduction of the SCS lead displacement. The aim of the research was an experimental examination and comparison of electrodes displacement for three different ways of fixing of the lead using anchor. The displacements were measured on pigs using optical methods. The displacement of the electrode depends greatly on the number of anchors and on the manner the lead is fixed. The fixing the lead using two anchors with a loop between them significantly reduces the total displacement of the electrode.
Název v anglickém jazyce
Measurement of displacement of percutaneous lead for spinal cord stimulation
Popis výsledku anglicky
A Medtronic implantable neurostimulation system is indicated for spinal cord stimulation (SCS) as an aid in the management of chronic, intractable pain of the trunk and limbs. The method of anchors fixing may have a significant influence on the elimination or reduction of the SCS lead displacement. The aim of the research was an experimental examination and comparison of electrodes displacement for three different ways of fixing of the lead using anchor. The displacements were measured on pigs using optical methods. The displacement of the electrode depends greatly on the number of anchors and on the manner the lead is fixed. The fixing the lead using two anchors with a loop between them significantly reduces the total displacement of the electrode.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
54TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL STRESS ANALYSIS, EAN 2016CONFERENCE PROCEEDING
ISBN
978-802610624-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
312-315
Název nakladatele
DEPARTMENT OF MECHANICS, FACULTY OF APPLIED SCIENCES, UNIVERSITY OF WEST BOHEMIA