Troponin levels in patients with stable CAD
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F17%3A00000334" target="_blank" >RIV/61383082:_____/17:00000334 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/17:10364466 RIV/61989592:15110/17:73585024
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0010865016300741" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0010865016300741</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.crvasa.2016.12.001" target="_blank" >10.1016/j.crvasa.2016.12.001</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Troponin levels in patients with stable CAD
Popis výsledku v původním jazyce
Introduction: Cardiac troponins are known as specific markers of myocardial damage. Their elevation in the serum is not always related to acute myocardial ischaemia. The increased sensitivity of diagnostic kits has resulted in an increase in the number of positive results in patients without acute coronary syndrome (ACS). Study objectives: To determine the level of highly sensitive troponin T (hs TnT) in stable patients (without ACS) before selective coronarography (SCG) and to determine the correlation between hs TnT values and the extent of atherosclerotic damage to the coronary arteries. Methodology: We studied a group of 251 consecutive patients with indications for SCG diagnosis. Indication criteria were stable angina pectoris, shortness of breath, newly diagnosed heart failure, syncope, and ventricular arrhythmia. Exclusion criteria were acute coronary syndrome, including unstable angina pectoris, prior cardiopulmonary resuscitation, cerebrovascular accident (CVA) within the last 6 months, and ongoing sepsis. The hs TnT value was determined before SCG (normal range, 0-0.013 mu g/l). Monitored parameters included coronary angiography (70% stenosis of coronary artery diameter was considered significant coronary disease), age, gender, heart rate, and serum creatinine levels. The study included 182 patients with normal renal function and 69 patients with renal insufficiency. The results were processed using STATISTICA (version 12), StatSoft (c), Inc. (2013).
Název v anglickém jazyce
Troponin levels in patients with stable CAD
Popis výsledku anglicky
Introduction: Cardiac troponins are known as specific markers of myocardial damage. Their elevation in the serum is not always related to acute myocardial ischaemia. The increased sensitivity of diagnostic kits has resulted in an increase in the number of positive results in patients without acute coronary syndrome (ACS). Study objectives: To determine the level of highly sensitive troponin T (hs TnT) in stable patients (without ACS) before selective coronarography (SCG) and to determine the correlation between hs TnT values and the extent of atherosclerotic damage to the coronary arteries. Methodology: We studied a group of 251 consecutive patients with indications for SCG diagnosis. Indication criteria were stable angina pectoris, shortness of breath, newly diagnosed heart failure, syncope, and ventricular arrhythmia. Exclusion criteria were acute coronary syndrome, including unstable angina pectoris, prior cardiopulmonary resuscitation, cerebrovascular accident (CVA) within the last 6 months, and ongoing sepsis. The hs TnT value was determined before SCG (normal range, 0-0.013 mu g/l). Monitored parameters included coronary angiography (70% stenosis of coronary artery diameter was considered significant coronary disease), age, gender, heart rate, and serum creatinine levels. The study included 182 patients with normal renal function and 69 patients with renal insufficiency. The results were processed using STATISTICA (version 12), StatSoft (c), Inc. (2013).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
1
Strana od-do
„E-229“- „E-234“
Kód UT WoS článku
000410032200003
EID výsledku v databázi Scopus
2-s2.0-85009961941