Efficacy of Mechanical Thrombectomy using Penumbra ACETM Aspiration Catheter Compared to Stent Retriever SolitaireTM FR in Patients with Acute Ischemic Stroke.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61383082%3A_____%2F21%3A00001013" target="_blank" >RIV/61383082:_____/21:00001013 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2076-3425/11/4/504" target="_blank" >https://www.mdpi.com/2076-3425/11/4/504</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/brainsci11040504" target="_blank" >10.3390/brainsci11040504</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Efficacy of Mechanical Thrombectomy using Penumbra ACETM Aspiration Catheter Compared to Stent Retriever SolitaireTM FR in Patients with Acute Ischemic Stroke.
Popis výsledku v původním jazyce
Mechanical thrombectomy is the standard therapy in patients with acute ischemic stroke (AIS). The primary aim of our study was to compare the procedural efficacy of the direct aspiration technique, using Penumbra ACETM aspiration catheter, and the stent retriever technique, with a SolitaireTM FR stent. Secondarily, we investigated treatment-dependent and treatment-independent factors that predict a good clinical outcome. Methods: We analyzed our series of mechanical thrombectomies using a SolitaireTM FR stent and a Penumbra ACETM catheter. The clinical and radiographic data of 76 patients were retrospectively reviewed. Using binary logisticregression, we looked for the predictors of a good clinical outcome. Results: In the Penumbra ACETM group we achieved significantly higher rates of complete vessel recanalization with lower device passage counts, shorter recanalization times, shorter procedure times and shorter fluoroscopy times (p < 0.001) compared to the SolitaireTM FR group. We observed no significant difference in good clinical outcomes (52.4% vs. 56.4%, p = 0.756). Predictors of a good clinical outcome were lower initial NIHSS scores, pial arterial collateralization on admission head CT angiography scan, shorter recanalization times and device passage counts. Conclusions: The aspiration technique using Penumbra ACETM catheter is comparable to the stent retriever technique with SolitaireTM FR regarding clinical outcomes.
Název v anglickém jazyce
Efficacy of Mechanical Thrombectomy using Penumbra ACETM Aspiration Catheter Compared to Stent Retriever SolitaireTM FR in Patients with Acute Ischemic Stroke.
Popis výsledku anglicky
Mechanical thrombectomy is the standard therapy in patients with acute ischemic stroke (AIS). The primary aim of our study was to compare the procedural efficacy of the direct aspiration technique, using Penumbra ACETM aspiration catheter, and the stent retriever technique, with a SolitaireTM FR stent. Secondarily, we investigated treatment-dependent and treatment-independent factors that predict a good clinical outcome. Methods: We analyzed our series of mechanical thrombectomies using a SolitaireTM FR stent and a Penumbra ACETM catheter. The clinical and radiographic data of 76 patients were retrospectively reviewed. Using binary logisticregression, we looked for the predictors of a good clinical outcome. Results: In the Penumbra ACETM group we achieved significantly higher rates of complete vessel recanalization with lower device passage counts, shorter recanalization times, shorter procedure times and shorter fluoroscopy times (p < 0.001) compared to the SolitaireTM FR group. We observed no significant difference in good clinical outcomes (52.4% vs. 56.4%, p = 0.756). Predictors of a good clinical outcome were lower initial NIHSS scores, pial arterial collateralization on admission head CT angiography scan, shorter recanalization times and device passage counts. Conclusions: The aspiration technique using Penumbra ACETM catheter is comparable to the stent retriever technique with SolitaireTM FR regarding clinical outcomes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30103 - Neurosciences (including psychophysiology)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Brain Science
ISSN
2076-3425
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
000642782800001
EID výsledku v databázi Scopus
2-s2.0-85104962311