Electrochemical Oxidation of 8-oxo-2-Deoxyguanosine on Glassy Carbon, Gold, Platinum and Tin(IV) Oxide Electrodes.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F03%3A54030165" target="_blank" >RIV/61388955:_____/03:54030165 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11120/03:00007295
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Oxidation of 8-oxo-2-Deoxyguanosine on Glassy Carbon, Gold, Platinum and Tin(IV) Oxide Electrodes.
Popis výsledku v původním jazyce
Cyclic voltammetry was used to investigate the oxidation of 8-oxo-2 deoxyguanosine(8-oxo-dG) on the glassy carbon(GC), platinum, gold and SnO2 electrodes over a range of the sweep rate, 8-oxo-dG concentration and the solution pH. Reaction mechanism thatis common to all these electrodes involves the two-electron two-proton charge transfer step followed by the irreversible chemical reaction(s). Rate of the charge transfer reaction decreases with the increasing solution pH (GC, Pt, Au) and depends on thenature of the electrode material following the seguence GC>Pt, Au>>SnO2. These effects can be related to the degree of oxidation of the electrode surface (Pt, Au, SnO2),or to the density of the active surface sites (GC). Any of these electrodes can be used for the fabrication of an amperometric detector for 8-oxo-dG.
Název v anglickém jazyce
Electrochemical Oxidation of 8-oxo-2-Deoxyguanosine on Glassy Carbon, Gold, Platinum and Tin(IV) Oxide Electrodes.
Popis výsledku anglicky
Cyclic voltammetry was used to investigate the oxidation of 8-oxo-2 deoxyguanosine(8-oxo-dG) on the glassy carbon(GC), platinum, gold and SnO2 electrodes over a range of the sweep rate, 8-oxo-dG concentration and the solution pH. Reaction mechanism thatis common to all these electrodes involves the two-electron two-proton charge transfer step followed by the irreversible chemical reaction(s). Rate of the charge transfer reaction decreases with the increasing solution pH (GC, Pt, Au) and depends on thenature of the electrode material following the seguence GC>Pt, Au>>SnO2. These effects can be related to the degree of oxidation of the electrode surface (Pt, Au, SnO2),or to the density of the active surface sites (GC). Any of these electrodes can be used for the fabrication of an amperometric detector for 8-oxo-dG.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA203%2F01%2F0653" target="_blank" >GA203/01/0653: Nové elektrochemické metody pro kvantitativní detekci 8-hydroxy-2´-deoxyguanosinu v moči</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
19
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
1555-1560
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—