Laser-diodová photoakustická detekce v infračervené a blízké infračervené spektrální oblasti
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F05%3A00001352" target="_blank" >RIV/61388955:_____/05:00001352 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Laser diode photoacoustic detection in the infrared and near infrared spectral ranges
Popis výsledku v původním jazyce
A new technique for high resolution photoacoustic detection based on application of laser diodes has been developed. This method was tested and compared using identical photoacoustic instrumentation ( cell and microphone) to study gas absorption in threedifferent spectral regions, namely: the infrared range near 2100 cm-1, CO and OCS fundamental band absorption; the ranges near 4200 and 4350 cm.(-1), CH4, NH3 and N2O overtone and combination band absorption; the near infrared range near 6500 cm(-1), CO, CO2 and NH3 overtone absorption. Several types of diode laser operating at room temperature or at liquid nitrogen temperature were compared. The optimum gas pressures for the maximum sensitivity of the photoacoustic signals were found and the detectionlimits were estimated for all of the gases studied. The best sensitivity was achieved for NH3 at 100 ppbv. The sensitivity of the developed system was tested on detection of traces of NH3 and CO2 gases from car exhaust.
Název v anglickém jazyce
Laser diode photoacoustic detection in the infrared and near infrared spectral ranges
Popis výsledku anglicky
A new technique for high resolution photoacoustic detection based on application of laser diodes has been developed. This method was tested and compared using identical photoacoustic instrumentation ( cell and microphone) to study gas absorption in threedifferent spectral regions, namely: the infrared range near 2100 cm-1, CO and OCS fundamental band absorption; the ranges near 4200 and 4350 cm.(-1), CH4, NH3 and N2O overtone and combination band absorption; the near infrared range near 6500 cm(-1), CO, CO2 and NH3 overtone absorption. Several types of diode laser operating at room temperature or at liquid nitrogen temperature were compared. The optimum gas pressures for the maximum sensitivity of the photoacoustic signals were found and the detectionlimits were estimated for all of the gases studied. The best sensitivity was achieved for NH3 at 100 ppbv. The sensitivity of the developed system was tested on detection of traces of NH3 and CO2 gases from car exhaust.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analyst
ISSN
0003-2654
e-ISSN
—
Svazek periodika
130
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
1148-1154
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—