Longitudinální studie izoprénu v dechu zdravých dobrovolníků s použitím hmotnostní spektrometrie v proudové trubici s vybranými ionty
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F06%3A00078426" target="_blank" >RIV/61388955:_____/06:00078426 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)
Popis výsledku v původním jazyce
Thirty volunteers (19 males, 11 females) were recruited for a 6-month study of the volatile compounds in their exhaled breath using the selected ion flow tube mass spectrometry (SIFT-MS) analytical technique. Volunteers provided weekly breath samples between 8:45 am and I pm (before lunch), and the concentrations of several trace compounds were obtained. In this paper, we focus on the isoprene in alveolar breath, which was monitored by SIFT-MS using NO+ precursor ions. The mean isoprene level for all samples was 118 parts per billion (ppb) with a standard deviation of 68 ppb and the range of values for breath samples given is 0-474 ppb. Variability in isoprene levels was similar in most volunteers. Isoprene levels increased immediately after moderate exercise, but returned to normal within 2-3 min for those few volunteers that were investigated. Cholesterol levels analysed for only three of the subjects were not obviously correlated with isoprene concentration in breath.
Název v anglickém jazyce
A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)
Popis výsledku anglicky
Thirty volunteers (19 males, 11 females) were recruited for a 6-month study of the volatile compounds in their exhaled breath using the selected ion flow tube mass spectrometry (SIFT-MS) analytical technique. Volunteers provided weekly breath samples between 8:45 am and I pm (before lunch), and the concentrations of several trace compounds were obtained. In this paper, we focus on the isoprene in alveolar breath, which was monitored by SIFT-MS using NO+ precursor ions. The mean isoprene level for all samples was 118 parts per billion (ppb) with a standard deviation of 68 ppb and the range of values for breath samples given is 0-474 ppb. Variability in isoprene levels was similar in most volunteers. Isoprene levels increased immediately after moderate exercise, but returned to normal within 2-3 min for those few volunteers that were investigated. Cholesterol levels analysed for only three of the subjects were not obviously correlated with isoprene concentration in breath.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Measurement
ISSN
0967-3334
e-ISSN
—
Svazek periodika
27
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
13-22
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—