Popis výsledku v původním jazyce
The value of selected ion flow tube mass spectrometry, SIFT-MS, for the sampling and analysis of trace me- tabolites in both mouth-exhaled and nose-exhaled breath is discussed, and the latter is shown to circumvent oral contami- nation. Results of experiments are described in which increased levels of ammonia and ethanol deliberately generated in the oral cavity are clearly registered in mouth-exhaled breath but not in nose-exhaled breath. The value of the sampling methods that are used for the analysisof trace metabolites in both mouth-exhaled and nose-exhaled breath with selected ion flow tube mass spectrometry, SIFT-MS, is discussed, and their importance as a means to provide concentrations of truly endogenous compounds by circumventing their oralcontamination is demonstrated. Further to this, data are pre- sented on the direct analysis by SIFT-MS of several compounds in the nose-exhaled breath of eight healthy volunteers during exercise on a stationary bicycle. Of note are the da
Název v anglickém jazyce
SIFT-MS Analysis of Nose-Exhaled Breath; Mouth Contamination and the Influence of Exercise
Popis výsledku anglicky
The value of selected ion flow tube mass spectrometry, SIFT-MS, for the sampling and analysis of trace me- tabolites in both mouth-exhaled and nose-exhaled breath is discussed, and the latter is shown to circumvent oral contami- nation. Results of experiments are described in which increased levels of ammonia and ethanol deliberately generated in the oral cavity are clearly registered in mouth-exhaled breath but not in nose-exhaled breath. The value of the sampling methods that are used for the analysisof trace metabolites in both mouth-exhaled and nose-exhaled breath with selected ion flow tube mass spectrometry, SIFT-MS, is discussed, and their importance as a means to provide concentrations of truly endogenous compounds by circumventing their oralcontamination is demonstrated. Further to this, data are pre- sented on the direct analysis by SIFT-MS of several compounds in the nose-exhaled breath of eight healthy volunteers during exercise on a stationary bicycle. Of note are the da
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Current Analytical Chemistry
ISSN
1573-4110
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
2013
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
565-575
Kód UT WoS článku
000324493100006