The in vitro identification and quantification of volatile biomarkers released by cystic fibrosis pathogens
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F15%3A00452351" target="_blank" >RIV/61388955:_____/15:00452351 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1039/c4ay02981j" target="_blank" >http://dx.doi.org/10.1039/c4ay02981j</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c4ay02981j" target="_blank" >10.1039/c4ay02981j</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The in vitro identification and quantification of volatile biomarkers released by cystic fibrosis pathogens
Popis výsledku v původním jazyce
There is interest in the development of exhaled breath tests for the detection of lower airway infection in children with cystic fibrosis. The first stage of this process is the identification of volatile organic compounds (VOCs) released into the gas phase by CF pathogens that can be used as breath test biomarkers. Selected ion flow tube mass spectrometry (SIFT-MS) is ideally suited to these in vitro studies as it allows simultaneous quantification of multiple VOCs in real time. We review a decade of in vitro experiments using SIFT-MS to analyse the VOCs released by respiratory pathogens. This includes identification and quantification of VOCs and the investigation of the in vitro factors that affect their production. We also report on how our culturemethodology has been refined over the years to better account for variations in bacterial mass. Finally, we discuss how these in vitro findings have been translated into clinical trials and assess possible future applications.
Název v anglickém jazyce
The in vitro identification and quantification of volatile biomarkers released by cystic fibrosis pathogens
Popis výsledku anglicky
There is interest in the development of exhaled breath tests for the detection of lower airway infection in children with cystic fibrosis. The first stage of this process is the identification of volatile organic compounds (VOCs) released into the gas phase by CF pathogens that can be used as breath test biomarkers. Selected ion flow tube mass spectrometry (SIFT-MS) is ideally suited to these in vitro studies as it allows simultaneous quantification of multiple VOCs in real time. We review a decade of in vitro experiments using SIFT-MS to analyse the VOCs released by respiratory pathogens. This includes identification and quantification of VOCs and the investigation of the in vitro factors that affect their production. We also report on how our culturemethodology has been refined over the years to better account for variations in bacterial mass. Finally, we discuss how these in vitro findings have been translated into clinical trials and assess possible future applications.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Methods: advancing methods and applications
ISSN
1759-9660
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
818-824
Kód UT WoS článku
000349679300001
EID výsledku v databázi Scopus
2-s2.0-84922473343