SIFT-MS and FA-MS methods for ambient gas phase analysis: developments and applications in the UK
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F15%3A00452619" target="_blank" >RIV/61388955:_____/15:00452619 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1039/c4an02049a" target="_blank" >http://dx.doi.org/10.1039/c4an02049a</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c4an02049a" target="_blank" >10.1039/c4an02049a</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
SIFT-MS and FA-MS methods for ambient gas phase analysis: developments and applications in the UK
Popis výsledku v původním jazyce
Selected ion flow tube mass spectrometry, SIFT-MS, a relatively new gas/vapour phase analytical method, is derived from the much earlier selected ion flow tube, SIFT, used for the study of gas phase ion-molecule reactions. Both the SIFT and SIFT-MS techniques were conceived and developed in the UK, the former at Birmingham University, the latter at Keele University along with the complementary flowing afterglow mass spectrometry, FA-MS, technique. The focus of this short review is largely to describe the origins, developments and, most importantly, the unique features of SIFT-MS as an analytical tool for ambient analysis and to indicate its growing use to analyse humid air, especially exhaled breath, its unique place as a on-line, real time analyticalmethod and its growing use and applications as a non-invasive diagnostic in clinical diagnosis and therapeutic monitoring, principally within several UK universities and hospitals, and briefly in the wider world. A few case studies are ou
Název v anglickém jazyce
SIFT-MS and FA-MS methods for ambient gas phase analysis: developments and applications in the UK
Popis výsledku anglicky
Selected ion flow tube mass spectrometry, SIFT-MS, a relatively new gas/vapour phase analytical method, is derived from the much earlier selected ion flow tube, SIFT, used for the study of gas phase ion-molecule reactions. Both the SIFT and SIFT-MS techniques were conceived and developed in the UK, the former at Birmingham University, the latter at Keele University along with the complementary flowing afterglow mass spectrometry, FA-MS, technique. The focus of this short review is largely to describe the origins, developments and, most importantly, the unique features of SIFT-MS as an analytical tool for ambient analysis and to indicate its growing use to analyse humid air, especially exhaled breath, its unique place as a on-line, real time analyticalmethod and its growing use and applications as a non-invasive diagnostic in clinical diagnosis and therapeutic monitoring, principally within several UK universities and hospitals, and briefly in the wider world. A few case studies are ou
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-28882S" target="_blank" >GA13-28882S: Excitace, separace a fragmentace iontů v driftovém poli v SIFT-MS pro okamžitou selektivní kvantifikaci stopových plynů</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analyst
ISSN
0003-2654
e-ISSN
—
Svazek periodika
140
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
19
Strana od-do
2573-2591
Kód UT WoS článku
000352141800003