On the importance of accurate quantification of individual volatile metabolites in exhaled breath
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F17%3A00484005" target="_blank" >RIV/61388955:_____/17:00484005 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1752-7163/aa7ab5" target="_blank" >http://dx.doi.org/10.1088/1752-7163/aa7ab5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1752-7163/aa7ab5" target="_blank" >10.1088/1752-7163/aa7ab5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On the importance of accurate quantification of individual volatile metabolites in exhaled breath
Popis výsledku v původním jazyce
It is argued that shortcomings of certain approaches to breath analysis research based on superficial interpretation of non-quantitative data are inadvertently inhibiting the progression of non-invasive breath analysis into clinical practice. The objective of this perspective is to suggest more clinically profitable approaches to breath research. Thus, following a discourse on the challenges and expectations in breath research, a brief indication is given of the analytical techniques currently used for the analysis of very humid exhaled breath. The seminal work that has been carried out using GCMS revealed that exhaled breath comprises large numbers of trace volatile organic compounds, VOCs. Unfortunately, analysis of these valuable GC-MS data is mostly performed using chemometrics to distinguish the VOC content of breath samples collected from patients and healthy controls, and reliable quantification of the VOCs is rarely deemed necessary. This limited approach ignores the requirements of clinically acceptable biomarkers and misses the opportunity to identify relationships between the concentrations of individual VOCs and certain related physiological or metabolic parameters. Therefore, a plea is made for more effort to be directed towards the positive identification and accurate quantification of individual VOCs in exhaled breath, which are more physiologically meaningful as best exemplified by the quantification of breath nitric oxide, NO. Support for the value of individual VOC quantification is illustrated by the SIFT-MS studies of breath hydrogen cyanide, HCN, a biomarker of Pseudomonas aeruginosa infection, breath acetic acid as an indicator of airways acidification in cystic fibrosis patients, and n-pentane as a breath biomarker of inflammation in idiopathic bowel disease patients. These single VOCs could be used as non-invasive monitors of the efficacy of therapeutic intervention...
Název v anglickém jazyce
On the importance of accurate quantification of individual volatile metabolites in exhaled breath
Popis výsledku anglicky
It is argued that shortcomings of certain approaches to breath analysis research based on superficial interpretation of non-quantitative data are inadvertently inhibiting the progression of non-invasive breath analysis into clinical practice. The objective of this perspective is to suggest more clinically profitable approaches to breath research. Thus, following a discourse on the challenges and expectations in breath research, a brief indication is given of the analytical techniques currently used for the analysis of very humid exhaled breath. The seminal work that has been carried out using GCMS revealed that exhaled breath comprises large numbers of trace volatile organic compounds, VOCs. Unfortunately, analysis of these valuable GC-MS data is mostly performed using chemometrics to distinguish the VOC content of breath samples collected from patients and healthy controls, and reliable quantification of the VOCs is rarely deemed necessary. This limited approach ignores the requirements of clinically acceptable biomarkers and misses the opportunity to identify relationships between the concentrations of individual VOCs and certain related physiological or metabolic parameters. Therefore, a plea is made for more effort to be directed towards the positive identification and accurate quantification of individual VOCs in exhaled breath, which are more physiologically meaningful as best exemplified by the quantification of breath nitric oxide, NO. Support for the value of individual VOC quantification is illustrated by the SIFT-MS studies of breath hydrogen cyanide, HCN, a biomarker of Pseudomonas aeruginosa infection, breath acetic acid as an indicator of airways acidification in cystic fibrosis patients, and n-pentane as a breath biomarker of inflammation in idiopathic bowel disease patients. These single VOCs could be used as non-invasive monitors of the efficacy of therapeutic intervention...
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Breath Research
ISSN
1752-7155
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
13
Strana od-do
—
Kód UT WoS článku
000414263000002
EID výsledku v databázi Scopus
2-s2.0-85038891315