Determination of selected bisphenols, parabens and estrogens in human plasma using LC-MS/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F17%3A00477766" target="_blank" >RIV/61388963:_____/17:00477766 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389030:_____/17:00477766 RIV/61383082:_____/17:00000376 RIV/00216208:11110/17:10368056 RIV/00023761:_____/17:N0000017
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.talanta.2017.05.070" target="_blank" >http://dx.doi.org/10.1016/j.talanta.2017.05.070</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2017.05.070" target="_blank" >10.1016/j.talanta.2017.05.070</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of selected bisphenols, parabens and estrogens in human plasma using LC-MS/MS
Popis výsledku v původním jazyce
In this study, a novel liquid chromatography tandem mass spectrometry method for the simultaneous determination of bisphenols (BPA, BPS, BPF, BPAF), parabens (methyl-, ethyl-, propyl-, butyl-, benzyl-paraben) and estrogens (estrone, estradiol, estriol) in human plasma is presented. Since all analytes possess the phenolic group, dansyl chloride derivatization was applied in order to gain high sensitivity. The method was validated according to FDA guidelines, and all validation requirements were satisfactory. The lower limits of quantifications were 41.6, 54.9, 43.5 and 150.8 pg/mL for BPA, BPS, BPF and BPAF, 172, 149, 171, 134 and 202 pg/mL for methyl-, ethyl-, propyl-, butyl- and benzyl-paraben, 10.5, 6.7 and 9.4 pg/mL for estrone, estradiol and estriol, respectively. This is the first method allowing the determination of plasma bisphenols, parabens and estrogens in one run, and also the first determination of BPF levels in human plasma. The method was used to examine the plasma levels of healthy normospermic men, where three times higher plasma levels of BPF than BPA were found.
Název v anglickém jazyce
Determination of selected bisphenols, parabens and estrogens in human plasma using LC-MS/MS
Popis výsledku anglicky
In this study, a novel liquid chromatography tandem mass spectrometry method for the simultaneous determination of bisphenols (BPA, BPS, BPF, BPAF), parabens (methyl-, ethyl-, propyl-, butyl-, benzyl-paraben) and estrogens (estrone, estradiol, estriol) in human plasma is presented. Since all analytes possess the phenolic group, dansyl chloride derivatization was applied in order to gain high sensitivity. The method was validated according to FDA guidelines, and all validation requirements were satisfactory. The lower limits of quantifications were 41.6, 54.9, 43.5 and 150.8 pg/mL for BPA, BPS, BPF and BPAF, 172, 149, 171, 134 and 202 pg/mL for methyl-, ethyl-, propyl-, butyl- and benzyl-paraben, 10.5, 6.7 and 9.4 pg/mL for estrone, estradiol and estriol, respectively. This is the first method allowing the determination of plasma bisphenols, parabens and estrogens in one run, and also the first determination of BPF levels in human plasma. The method was used to examine the plasma levels of healthy normospermic men, where three times higher plasma levels of BPF than BPA were found.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10401 - Organic chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
174
Číslo periodika v rámci svazku
NOV 1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
21-28
Kód UT WoS článku
000407524900004
EID výsledku v databázi Scopus
2-s2.0-85019970353