Non-enzymatic electrochemical determination of cholesterol in dairy products on boron-doped diamond electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388963%3A_____%2F22%3A00558154" target="_blank" >RIV/61388963:_____/22:00558154 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/22:10452228 RIV/61989592:15310/22:73615538
Výsledek na webu
<a href="https://doi.org/10.1016/j.foodchem.2022.133278" target="_blank" >https://doi.org/10.1016/j.foodchem.2022.133278</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.foodchem.2022.133278" target="_blank" >10.1016/j.foodchem.2022.133278</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Non-enzymatic electrochemical determination of cholesterol in dairy products on boron-doped diamond electrode
Popis výsledku v původním jazyce
Determination of cholesterol in food matrices is essential for quality control concerning the health of consumers. Herein, a simple electrochemical approach for cholesterol quantitation in dairy products is evaluated. The newly developed differential pulse voltammetric method using acetonitrile-perchloric acid mixture as a supporting electrolyte is statistically compared to GC–MS and HPLC-UV. Oxidation signals of cholesterol at +1.5 V and +1.4 V (vs. Ag/AgNO3 in acetonitrile) provide detection limits of 4.9 µM and 6.1 µM on boron-doped diamond and glassy carbon electrodes, respectively. A simple liquid–liquid extraction procedure from dairy products into hexane resulted in a recovery rate of (74.8 ± 3.8)%. The method provides results in close agreement (at a 95% confidence level) with GC–MS, while HPLC-UV resulted in a significant difference in estimated cholesterol concentrations for all samples. This newly developed method is a simpler, faster and cheaper alternative to instrumentally demanding MS-based methods and clearly outperforms HPLC-UV.
Název v anglickém jazyce
Non-enzymatic electrochemical determination of cholesterol in dairy products on boron-doped diamond electrode
Popis výsledku anglicky
Determination of cholesterol in food matrices is essential for quality control concerning the health of consumers. Herein, a simple electrochemical approach for cholesterol quantitation in dairy products is evaluated. The newly developed differential pulse voltammetric method using acetonitrile-perchloric acid mixture as a supporting electrolyte is statistically compared to GC–MS and HPLC-UV. Oxidation signals of cholesterol at +1.5 V and +1.4 V (vs. Ag/AgNO3 in acetonitrile) provide detection limits of 4.9 µM and 6.1 µM on boron-doped diamond and glassy carbon electrodes, respectively. A simple liquid–liquid extraction procedure from dairy products into hexane resulted in a recovery rate of (74.8 ± 3.8)%. The method provides results in close agreement (at a 95% confidence level) with GC–MS, while HPLC-UV resulted in a significant difference in estimated cholesterol concentrations for all samples. This newly developed method is a simpler, faster and cheaper alternative to instrumentally demanding MS-based methods and clearly outperforms HPLC-UV.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA19-11268S" target="_blank" >GA19-11268S: Elektrochemické metody: Nové přístupy pro charakterizaci a analýzu steroidů</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Food Chemistry
ISSN
0308-8146
e-ISSN
1873-7072
Svazek periodika
393
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
133278
Kód UT WoS článku
000812356600010
EID výsledku v databázi Scopus
2-s2.0-85131215778