Markers of Oxidative Stress are Elevated in Workers Exposed to Nanoparticles
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388971%3A_____%2F12%3A00398799" target="_blank" >RIV/61388971:_____/12:00398799 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985858:_____/12:00398799 RIV/61388955:_____/12:00398799
Výsledek na webu
<a href="http://www.nanocon.eu/files/proceedings/04/index_cz.htm" target="_blank" >http://www.nanocon.eu/files/proceedings/04/index_cz.htm</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Markers of Oxidative Stress are Elevated in Workers Exposed to Nanoparticles
Popis výsledku v původním jazyce
Health-effects of nanoparticles in humans are little understood. Pre-shift and post-shift spirometry, markers in exhaled breath condensate (EBC), and fractional exhaled nitric oxide (FeNO) were measured both in 20 workers exposed to TiO2 aerosol and 19 controls. Particle number size distributions were monitored by aerosol spectrometers SMPS and APS, covering the overall size range 15 nm-10 ?m. Simultaneously, the spatial distributions of total particle number and mass concentrations were determined using a particle number concentration monitor (P-TRAK) and a monitor of particle mass concentrations (DustTRAK DRX). Total aerosol concentrations in the production plant varied greatly in both space and time; number concentrations 1x104-2x105 particles/cm3 and mass concentrations 0.1-30 mg/m3. In the workshops, 90% of the particles were smaller than 100 nm in diameter and particle concentrations were 10x higher than in the control room.
Název v anglickém jazyce
Markers of Oxidative Stress are Elevated in Workers Exposed to Nanoparticles
Popis výsledku anglicky
Health-effects of nanoparticles in humans are little understood. Pre-shift and post-shift spirometry, markers in exhaled breath condensate (EBC), and fractional exhaled nitric oxide (FeNO) were measured both in 20 workers exposed to TiO2 aerosol and 19 controls. Particle number size distributions were monitored by aerosol spectrometers SMPS and APS, covering the overall size range 15 nm-10 ?m. Simultaneously, the spatial distributions of total particle number and mass concentrations were determined using a particle number concentration monitor (P-TRAK) and a monitor of particle mass concentrations (DustTRAK DRX). Total aerosol concentrations in the production plant varied greatly in both space and time; number concentrations 1x104-2x105 particles/cm3 and mass concentrations 0.1-30 mg/m3. In the workshops, 90% of the particles were smaller than 100 nm in diameter and particle concentrations were 10x higher than in the control room.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník příspěvků
ISBN
978-80-87294-32-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
TANGER
Místo vydání
Slezská Ostrava
Místo konání akce
Brno
Datum konání akce
23. 10. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—