External Support of Autologous Internal Jugular Vein Grafts with FRAME Mesh in a Porcine Carotid Artery Model
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388971%3A_____%2F24%3A00587360" target="_blank" >RIV/61388971:_____/24:00587360 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023001:_____/24:00084927 RIV/00216208:11110/24:10481627 RIV/00216208:11120/24:43927291 RIV/00216208:11130/24:10481627 RIV/00064190:_____/24:10001302
Výsledek na webu
<a href="https://www.mdpi.com/2227-9059/12/6/1335" target="_blank" >https://www.mdpi.com/2227-9059/12/6/1335</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/biomedicines12061335" target="_blank" >10.3390/biomedicines12061335</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
External Support of Autologous Internal Jugular Vein Grafts with FRAME Mesh in a Porcine Carotid Artery Model
Popis výsledku v původním jazyce
Background: Autologous vein grafts are widely used for bypass procedures in cardiovascular surgery. However, these grafts are susceptible to failure due to vein graft disease. Our study aimed to evaluate the impact of the latest-generation FRAME external support on vein graft remodeling in a preclinical model. Methods: We performed autologous internal jugular vein interposition grafting in porcine carotid arteries for one month. Four grafts were supported with a FRAME mesh, while seven unsupported grafts served as controls. The conduits were examined through flowmetry, angiography, macroscopy, and microscopy. Results: The one-month patency rate of FRAME-supported grafts was 100% (4/4), whereas that of unsupported controls was 43% (3/7, Log-rank p = 0.071). On explant angiography, FRAME grafts exhibited significantly more areas with no or mild stenosis (9/12) compared to control grafts (3/21, p = 0.0009). Blood flow at explantation was higher in the FRAME grafts (145 +/- 51 mL/min) than in the controls (46 +/- 85 mL/min, p = 0.066). Area and thickness of neo-intimal hyperplasia (NIH) at proximal anastomoses were similar for the FRAME and the control groups: 5.79 +/- 1.38 versus 6.94 +/- 1.10 mm2, respectively (p = 0.558) and 480 +/- 95 vs. 587 +/- 52 mu m2/mu m, respectively (p = 0.401). However, in the midgraft portions, the NIH area and thickness were significantly lower in the FRAME group than in the control group: 3.73 +/- 0.64 vs. 6.27 +/- 0.64 mm2, respectively (p = 0.022) and 258 +/- 49 vs. 518 +/- 36 mu m2/mu m, respectively (p = 0.0002). Conclusions: In our porcine model, the external mesh FRAME improved the patency of vein-to-carotid artery grafts and protected them from stenosis, particularly in the mid regions. The midgraft neo-intimal hyperplasia was two-fold thinner in the meshed grafts than in the controls.
Název v anglickém jazyce
External Support of Autologous Internal Jugular Vein Grafts with FRAME Mesh in a Porcine Carotid Artery Model
Popis výsledku anglicky
Background: Autologous vein grafts are widely used for bypass procedures in cardiovascular surgery. However, these grafts are susceptible to failure due to vein graft disease. Our study aimed to evaluate the impact of the latest-generation FRAME external support on vein graft remodeling in a preclinical model. Methods: We performed autologous internal jugular vein interposition grafting in porcine carotid arteries for one month. Four grafts were supported with a FRAME mesh, while seven unsupported grafts served as controls. The conduits were examined through flowmetry, angiography, macroscopy, and microscopy. Results: The one-month patency rate of FRAME-supported grafts was 100% (4/4), whereas that of unsupported controls was 43% (3/7, Log-rank p = 0.071). On explant angiography, FRAME grafts exhibited significantly more areas with no or mild stenosis (9/12) compared to control grafts (3/21, p = 0.0009). Blood flow at explantation was higher in the FRAME grafts (145 +/- 51 mL/min) than in the controls (46 +/- 85 mL/min, p = 0.066). Area and thickness of neo-intimal hyperplasia (NIH) at proximal anastomoses were similar for the FRAME and the control groups: 5.79 +/- 1.38 versus 6.94 +/- 1.10 mm2, respectively (p = 0.558) and 480 +/- 95 vs. 587 +/- 52 mu m2/mu m, respectively (p = 0.401). However, in the midgraft portions, the NIH area and thickness were significantly lower in the FRAME group than in the control group: 3.73 +/- 0.64 vs. 6.27 +/- 0.64 mm2, respectively (p = 0.022) and 258 +/- 49 vs. 518 +/- 36 mu m2/mu m, respectively (p = 0.0002). Conclusions: In our porcine model, the external mesh FRAME improved the patency of vein-to-carotid artery grafts and protected them from stenosis, particularly in the mid regions. The midgraft neo-intimal hyperplasia was two-fold thinner in the meshed grafts than in the controls.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10606 - Microbiology
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedicines
ISSN
2227-9059
e-ISSN
2227-9059
Svazek periodika
12
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
28
Strana od-do
1335
Kód UT WoS článku
001254538900001
EID výsledku v databázi Scopus
2-s2.0-85197866516