Voltammetric identification of pedogenic iron oxides in paleosol and loess.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388980%3A_____%2F02%3A50023012" target="_blank" >RIV/61388980:_____/02:50023012 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric identification of pedogenic iron oxides in paleosol and loess.
Popis výsledku v původním jazyce
Voltammetry of immobilized microparticles was used to detect low concentrations of goethite and hematite in paleosol and loess samples. The total content of Fe oxides in the natural samples was below 2 wt% and below the detection limit of X-ray powder diffraction. Goethite was distinguished from hematite due to the different electrochemical reactivity of the product of thermal dehydroxylation of goethite (very fine crystalline hematite). The voltammetric analysis was tested using synthetic samples of ferrihydrite, goethite, hematite, magnetite, or Mg-ferrite with SiO2 and a natural sample of smectite with an admixture of goethite. The detection is most sensitive for goethite and hematite (detection limit about 0.1 wt%), and approximately an order of magnitude better than X-ray powder diffraction analysis.
Název v anglickém jazyce
Voltammetric identification of pedogenic iron oxides in paleosol and loess.
Popis výsledku anglicky
Voltammetry of immobilized microparticles was used to detect low concentrations of goethite and hematite in paleosol and loess samples. The total content of Fe oxides in the natural samples was below 2 wt% and below the detection limit of X-ray powder diffraction. Goethite was distinguished from hematite due to the different electrochemical reactivity of the product of thermal dehydroxylation of goethite (very fine crystalline hematite). The voltammetric analysis was tested using synthetic samples of ferrihydrite, goethite, hematite, magnetite, or Mg-ferrite with SiO2 and a natural sample of smectite with an admixture of goethite. The detection is most sensitive for goethite and hematite (detection limit about 0.1 wt%), and approximately an order of magnitude better than X-ray powder diffraction analysis.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CA - Anorganická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalyssis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
339-344
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—