Název v původním jazyce
Control and Modelling of a New Space-Vector PWM Strategy for Improved Induction Motor Drive Reliability
Popis výsledku v původním jazyce
Three-phase voltage source (VSI) induction motor drives are prone to different inverter faults that cause the drive system to shut down. This paper investigate by the analytical model the utilization of a simplified topology that permis the fault tolerance operation of three-phase induction machine fed from the voltage source inverter when one of the inverter leg is lost. In that case, the machine phase with a lost inverter leg is connected to a zero DC voltage point to maintain balanced operation. Thespace-vector modulation strategy which is proposed has the same symmetry as for the B6 inverter and is simple without significant increase in switching frequency. It is also shown that derived time portions allocated to the proposed modulation strategy in the B4 connection are similar to that time portions derived for the classical B6 inverter. From the mathematical model we can derive both the steady-state and transient characteristics of the motor.
Název v anglickém jazyce
Control and Modelling of a New Space-Vector PWM Strategy for Improved Induction Motor Drive Reliability
Popis výsledku anglicky
Three-phase voltage source (VSI) induction motor drives are prone to different inverter faults that cause the drive system to shut down. This paper investigate by the analytical model the utilization of a simplified topology that permis the fault tolerance operation of three-phase induction machine fed from the voltage source inverter when one of the inverter leg is lost. In that case, the machine phase with a lost inverter leg is connected to a zero DC voltage point to maintain balanced operation. Thespace-vector modulation strategy which is proposed has the same symmetry as for the B6 inverter and is simple without significant increase in switching frequency. It is also shown that derived time portions allocated to the proposed modulation strategy in the B4 connection are similar to that time portions derived for the classical B6 inverter. From the mathematical model we can derive both the steady-state and transient characteristics of the motor.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Power, Energy,and Applications
ISBN
0-88986-616-3
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
232-238
Název nakladatele
IASTED
Místo vydání
Gaborone
Místo konání akce
Gaborone
Datum konání akce
11. 9. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—